The Value of Capsule Thickness on Breast Ultrasound as an Indicator of the Severity of Capsular Contracture and Its Correlation with the Baker Classification
Authors:
- 30 August 2021
- journal article
- research article
- Published by Springer Nature in Aesthetic Plastic Surgery
- Vol. 46 (2) , 621-629
Abstract
Background We conducted this study to explore the value of the capsule thickness as an indicator of the severity of capsular contracture (CC) alternatively to the Baker classification system in patients who were treated with an implant-based augmentation mammaplasty. Methods A total of 117 eligible patients (202 breasts) were included in the current study. We measured the capsule thickness using ultrasound and histologic examination in association with the Baker grades I, II, III and IV. Then, we analysed agreement of the capsule thickness between the two methods using an intra-correlation coefficient (ICC 2,1) with 95% confidence intervals (CIs). The CC of Baker grades II, III and IV (105 breasts), for which the capsule thickness could be measured using US, served as Model 1. Moreover, Model 1 including the CC of Baker grades I (97 breasts) served as Model 2. Results The capsule thickness was measured as 0.58 ± 0.11 (0.4–0.8) mm, 1.07 ± 0.16 (0.8–1.31) mm and 1.89 ± 0.55 (1–4.1) mm on ultrasound in association with Baker grades II, III and IV, respectively. In addition, it was also measured as 0.28 ± 0.07 (0.09–0.41) mm, 0.58 ± 0.08 (0.42–0.75) mm, 1.06 ± 0.14 (0.79–1.34) mm and 2.13 ± 1.14 (1.38–6.98) mm on histologic examination in association with Baker grades I, II, III and IV, respectively. In Model 1 and 2, the ICC was calculated as 0.942 (95%CI 0.914–0.961) and 0.955 (95%CI 0.940–0.966), respectively. The cut-off values between the Baker grades I–II, II–III and III–IV were calculated as 0. mm, 0.8 mm and 1.2 mm, respectively. Conclusions In conclusion, the capsule thickness might be used as an indicator of the severity of CC alternatively to the Baker classification system. But further studies are warranted to establish our results. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.Keywords
This publication has 29 references indexed in Scilit:
- Characterisation of breast implant surfaces and correlation with fibroblast adhesionJournal of the Mechanical Behavior of Biomedical Materials, 2013
- Bacterial biofilms and capsular contracture in patients with breast implantsBritish Journal of Surgery, 2013
- Challenges in Mammography: Part 2, Multimodality Review of Breast Augmentation—Imaging Findings and ComplicationsAmerican Journal of Roentgenology, 2011
- Use of shear wave sonoelastography in capsular contracture before and after secondary surgery: Report of two casesJournal of Plastic, Reconstructive & Aesthetic Surgery, 2011
- Imaging of breast implants—a pictorial reviewInsights into Imaging, 2011
- Long-Term Follow-Up of Breast Capsule Contracture Rates in Cosmetic and Reconstructive CasesPlastic and Reconstructive Surgery, 2010
- Capsular Contracture of the BreastAnnals of Plastic Surgery, 2006
- A Long-Term Study of Outcomes, Complications, and Patient Satisfaction with Breast ImplantsPlastic and Reconstructive Surgery, 2006
- Ten-Year Review of a Prospective Randomized Controlled Trial of Textured versus Smooth Subglandular Silicone Gel Breast ImplantsPlastic and Reconstructive Surgery, 2000
- Constant Compression Caliper for Objective Measurement of Breast Capsular ContractureScandinavian Journal of Plastic and Reconstructive Surgery, 1989