Comparison of topical fibrin spray and tranexamic acid on blood loss after total knee replacement
Authors:
- 1 March 2007
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (3) , 306-309
Abstract
We performed a randomised, controlled trial involving 150 patients with a pre-operative level of haemoglobin of 13.0 g/dl or less, to compare the effect of either topical fibrin spray or intravenous tranexamic acid on blood loss after total knee replacement. A total of 50 patients in the topical fibrin spray group had 10 ml of the reconstituted product applied intra-operatively to the operation site. The 50 patients in the tranexamic acid group received 500 mg of tranexamic acid intravenously five minutes before deflation of the tourniquet and a repeat dose three hours later, and a control group of 50 patients received no pharmacological intervention. There was a significant reduction in the total calculated blood loss for those in the topical fibrin spray group (p = 0.016) and tranexamic acid group (p = 0.041) compared with the control group, with mean losses of 1190 ml (708 to 2067), 1225 ml (580 to 2027), and 1415 ml (801 to 2319), respectively. The reduction in blood loss in the topical fibrin spray group was not significantly different from that achieved in the tranexamic acid group (p = 0.72).Keywords
This publication has 15 references indexed in Scilit:
- Use of Fibrin Sealant to Reduce Bloody Drainage and Hemoglobin Loss After Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2001
- A comparative study of the postoperative allogeneicblood‐sparing effects of tranexamic acid and of desmopressin after total knee replacementTransfusion, 2001
- Reduction of blood loss using tranexamic acid in total knee and hip arthroplastiesArchives of orthopaedic and trauma surgery, 2000
- How much blood is really lost in total knee arthroplasty?The Knee, 2000
- Effect of Tourniquet Use on Activation of Coagulation in Total Knee ReplacementClinical Orthopaedics and Related Research, 2000
- The Use of Fibrin Tissue Adhesive to Reduce Blood Loss and the Need for Blood Transfusion After Total Knee Arthroplasty. A Prospective, Randomized, Multicenter Study*Journal of Bone and Joint Surgery, 1999
- An Analysis of Blood Management in Patients Having a Total Hip or Knee Arthroplasty*Journal of Bone and Joint Surgery, 1999
- FIBRINOLYTIC INHIBITION WITH TRANEXAMIC ACID REDUCES BLOOD LOSS AND BLOOD TRANSFUSION AFTER KNEE ARTHROPLASTYThe Journal of Bone and Joint Surgery. British volume, 1996
- Detrimental effects of perioperative blood transfusionBritish Journal of Surgery, 1995
- Tranexamic acid (Cyklokapron) reduces perioperative blood loss associated with total knee arthroplastyBritish Journal of Anaesthesia, 1995