Quantification of Mn in glass matrices using laser induced breakdown spectroscopy (LIBS) combined with chemometric approaches
- 30 August 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (39) , 7177-7184
Abstract
A Q-switched solid state Nd:YAG laser operating at a third harmonic (355 nm) wavelength and an echelle spectrograph coupled with an ICCD system were used to study the plasma on a glass target. The present work is mainly focused on the investigation of multivariate calibration methods like principal component regression (PCR) and partial least squares regression (PLSR) for the analysis of Mn in complex matrices like glass. The glass studied has Mn as an analyte of interest whose doping concentration in the matrix varies from 0.77% to 11.61%. The performance of univariate and multivariate methods has been presented in this paper through their figures of merit. Improved prediction accuracy, limit of detection (LOD) and regression coefficients (R2) have been reported when the data were analyzed using PCR and PLSR. The calibration curves of six emission lines of Mn have been analyzed using a univariate method that resulted in R2 values varying from 0.85 to 0.98. This method resulted in a correlation uncertainty of 10% and a LOD of 0.20 wt%. R2 values of 0.98 to 0.99 have been obtained for the multivariate calibration curves of Mn analyzed in three selected regions of the LIBS spectrum. The optimum LOD and root mean square error of prediction (RMSEP) using PCR and PLSR were found to be 0.02 wt% and 0.54 wt%, respectively. The significant improvement in the analytical performances of multivariate calibration methods for the investigation of LIBS data is evident from the aforementioned results. Finally, the results of PCR and PLSR were confirmed by PCA classification.Keywords
This publication has 34 references indexed in Scilit:
- Comparison of principal components regression, partial least squares regression, multi-block partial least squares regression, and serial partial least squares regression algorithms for the analysis of Fe in iron ore using LIBSJournal of Analytical Atomic Spectrometry, 2011
- Optimized LIBS setup with echelle spectrograph-ICCD system for multi-elemental analysisJournal of Instrumentation, 2010
- Comparison of univariate and multivariate calibration for the determination of micronutrients in pellets of plant materials by laser induced breakdown spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 2010
- Evaluation of high-performance liquid chromatography laser-induced fluorescence for serum protein profiling for early diagnosis of oral cancerJournal of Biomedical Optics, 2010
- Multivariate calibration of spectra obtained by Laser Induced Breakdown Spectroscopy of plutonium oxide surrogate residuesSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Multi-elemental analysis of solidified mineral melt samples by Laser-Induced Breakdown Spectroscopy coupled with a linear multivariate calibrationSpectrochimica Acta Part B: Atomic Spectroscopy, 2007
- The evolution of chemometricsAnalytica Chimica Acta, 2003
- Laser induced breakdown spectrometry with an échelle spectrometer and intensified charge coupled device detectionSpectrochimica Acta Part B: Atomic Spectroscopy, 1998
- Chemical Analysis of High-Level Radioactive Waste Glass by ICP-AESAnalytical Sciences, 1998
- Spectrochemical analysis using a pulsed laser sourceSpectrochimica Acta, 1964