Accelerometry is associated with walking mobility, not physical activity, in persons with multiple sclerosis
Authors:
- Yoojin SuhYSYoojin Suh
- Abbi LaneALAbbi Lane
- Brian SandroffBSBrian Sandroff
- Deirdre DlugonskiDDDeirdre Dlugonski
- Bo FernhallBFBo Fernhall
- Robert W. MotlRMRobert W. Motl
- 2 October 2011
- journal article
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 34 (5) , 590-597
Abstract
Accelerometers are seemingly a criterion standard of real-life walking mobility and this is supported by assumptions and empirical data. This application would be strengthened by including objective measures of walking mobility along with a matched control sample for verifying specificity versus generality in accelerometer output. We compared associations among accelerometer output, walking mobility, and physical activity between persons with multiple sclerosis (MS) and controls without a neurological disorder. Sixty-six persons (33 MS, 33 matched controls) completed a battery of questionnaires, performed the six-minute walk (6MW) and timed-up-and-go (TUG), and wore an accelerometer for a 7-day period. After this period, participants completed the Godin Leisure-Time Exercise Questionnaire (GLTEQ) and International Physical Activity Questionnaire (IPAQ). Accelerometer output was significantly correlated with only mobility measures (6MW, ρ=.78; TUG, ρ=-.68) in MS, whereas it correlated with both mobility (6MW, ρ=.58; TUG, ρ=-.49) and physical activity (GLTEQ, ρ=.56; IPAQ, ρ=.53) measures in controls. Regression analysis indicated that only 6MW explained variance in accelerometer output in MS (β=.65, R(2)=.43). These findings support the possibility that accelerometers primarily and specifically measure real-life walking mobility, not physical activity, in persons with MS.Keywords
This publication has 32 references indexed in Scilit:
- Impact of Walking Impairment in Multiple SclerosisThe Patient - Patient-Centered Outcomes Research, 2011
- Quantifying gait impairment in multiple sclerosis using GAITRite™ technologyGait & Posture, 2011
- Most Common Types of Physical Activity Self-Selected by People with Multiple SclerosisInternational Journal of MS Care, 2011
- Does a waist-worn accelerometer capture intra- and inter-person variation in walking behavior among persons with multiple sclerosis?Medical Engineering & Physics, 2010
- Possible clinical outcome measures for clinical trials in patients with multiple sclerosisTherapeutic Advances in Neurological Disorders, 2010
- Real-life walking impairment in multiple sclerosis: preliminary comparison of four methods for processing accelerometry dataMultiple Sclerosis Journal, 2010
- Measuring Free-Living Physical Activity in Adults With and Without Neurologic Dysfunction With a Triaxial AccelerometerArchives of Physical Medicine and Rehabilitation, 2008
- An exploratory study of two measures of free-living physical activity for people with multiple sclerosisClinical Rehabilitation, 2007
- Gait and balance impairment in early multiple sclerosis in the absence of clinical disabilityMultiple Sclerosis Journal, 2006
- Quantification of walking mobility in neurological disordersQJM: An International Journal of Medicine, 2004