Reproducibility and feasibility of right ventricular strain and strain rate (SR) as determined by myocardial speckle tracking during high-intensity upright exercise: a comparison with tissue Doppler-derived strain and SR in healthy human hearts
Authors:
Open Access
- 1 September 2014
- journal article
- Published by Springer Nature in Echo Research & Practice
- Vol. 1 (1) , 31-41
Abstract
This study aimed to establish feasibility for myocardial speckle tracking (MST) and intra-observer reliability of both MST and tissue velocity imaging (TVI)-derived right ventricular (RV) strain (ε) and strain rate (SR) at rest and during upright incremental exercise. RV ε and SR were derived using both techniques in 19 healthy male participants. MST-derived ε and SR were feasible at rest (85% of segments tracked appropriately). Feasibility reduced significantly with progressive exercise intensity (3% of segments tracking appropriately at 90% maximum heart rate (HRmax)). Coefficient of variations (CoVs) of global ε values at rest was acceptable for both TVI and MST (7–12%), with low bias and narrow limits of agreement. Global SR data were less reliable for MST compared with TVI as demonstrated with CoV data (systolic SR=15 and 61%, early diastolic SR=16 and 17% and late diastolic SR=26 and 31% respectively). CoVs of global RV ε and SR obtained at 50% HRmax were acceptable using both techniques. As exercise intensity increased to 70 and 90% HRmax, reliability of ε and SR values reduced with larger variability in MST. We conclude that RV global and regional ε and SR data are feasible, comparable and reliable at rest and at 50% HRmax using both MST and TVI. Reliability was reduced during higher exercise intensities with only TVI acceptable for clinical and scientific use.Keywords
This publication has 34 references indexed in Scilit:
- Exercise Response in Hypertrophic CardiomyopathyCirculation: Cardiovascular Imaging, 2012
- Effects of graded heat stress on global left ventricular function and twist mechanics at rest and during exercise in healthy humansExperimental Physiology, 2010
- Kinetics of Left Ventricular Strains and Torsion During Incremental Exercise in Healthy SubjectsCirculation: Cardiovascular Imaging, 2010
- Left ventricular torsion and untwisting during exercise in heart transplant recipientsThe Journal of Physiology, 2009
- A comparison of Doppler, tissue Doppler imaging, and strain rate imaging in the assessment of postexercise left ventricular functionApplied Physiology, Nutrition, and Metabolism, 2009
- Left ventricular contractile function is preserved during prolonged exercise in middle-aged menJournal of Applied Physiology, 2009
- Exercise tissue Doppler echocardiography with strain rate imaging in healthy young individuals: feasibility, normal values and reproducibilityThe International Journal of Cardiovascular Imaging, 2006
- Comparison of Two-Dimensional Speckle and Tissue Velocity Based Strain and Validation With Harmonic Phase Magnetic Resonance ImagingThe American Journal of Cardiology, 2006
- What indices quantify regional myocardial function during supine bicycle in healthy subject: natural strain and strain rate?International Journal of Cardiology, 2005
- Real-Time Strain Rate Imaging of the Left Ventricle by UltrasoundJournal of the American Society of Echocardiography, 1998