Fully-Automated Fluorimetric Determination of Aluminum in Seawater by In-Syringe Dispersive Liquid–Liquid Microextraction Using Lumogallion
- 10 October 2012
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 84 (21) , 9462-9469
Abstract
A sensitive and selective automated in-syringe dispersive liquid–liquid microextraction (DLLME) method is presented. It was successfully applied to the determination of aluminum in coastal seawater samples. The complete analytical procedure including sampling, buffering, reaction of the analyte with fluorescence reagent lumogallion (LMG), extraction, phase separation, and quantification was completely automized and carried out within 4 min. DLLME was done using n-hexanol as an extracting solvent and ethanol as a dispersing solvent in a 1:8 v/v percent mixture. The Al–LMG complex was extracted by an organic solvent and separated from the aqueous phase within the syringe of an automated syringe pump. Two devices were specially developed for this work. These were (a) the fluorescence detector and accompanying flow cell for the organic phase enriched with the reaction product and (b) a heating device integrated into the holding coil to accelerate the slow reaction kinetics. The limits of detection (3σ) and quantification (10σ) were 8.0 ± 0.5 nmol L–1 and 26.7 ± 1.6 nmol L–1, respectively. The relative standard deviation for eight replicate determinations of 200 nmol L–1 Al3+ was –1 with a correlation coefficient of 0.999. Ambient concentrations of samples were quantifiable with found concentrations ranging from 43 to 142 nmol L–1. Standard additions gave analyte recoveries from 97% to 113% proving the general applicability and adequateness of the analyzer system to real sample analysis.Keywords
This publication has 36 references indexed in Scilit:
- Development of a sequential injection dispersive liquid–liquid microextraction system for electrothermal atomic absorption spectrometry by using a hydrophobic sorbent material: Determination of lead and cadmium in natural watersAnalytica Chimica Acta, 2010
- Fluorimetric Determination of Aluminium using Sequential Injection Analysis (SIA): State of Our Art and Future DevelopmentsInstrumentation Science & Technology, 2006
- Aluminum: new recognition of an old problemCurrent Opinion in Pharmacology, 2005
- Flow-injection solvent extraction with and without phase separation: Fluorimetric determination of aluminium in waterAnalytica Chimica Acta, 2001
- Sensitive and selective determination of aluminium by peroxyoxalate chemiluminescence detection of the lumogallion complexAnalytica Chimica Acta, 2001
- Fluorimetric determination of dissolved aluminium in natural waters after liquid–liquid extraction into n-hexanolAnalytica Chimica Acta, 2000
- Design of a very versatile software program for automating analytical methodsLaboratory Robotics and Automation, 1999
- Biogeochemical behavior and mass balance of dissolved aluminum in the western Mediterranean SeaDeep Sea Research Part II: Topical Studies in Oceanography, 1997
- Determination of trace aluminum in natural waters by flow-injection analysis with fluorescent detection of the lumogallion complexAnalytica Chimica Acta, 1995
- Determination of dissolved aluminium by the micelle-enhanced fluorescence of its lumogallion complexThe Analyst, 1986