Cryogenic Microjet Source for Orthotropic Beams of Ultralarge Superfluid Helium Droplets

Authors:

Abstract
Liquid He4 at pressures P0=0.5–30  bars and temperatures T0=1.5–4.2  K is discharged into vacuum through two different 2  μm nozzles. The velocities of the beam of particles obey the Bernoulli equation down to 15  m/sec. With decreasing T0 and increasing P0 the velocity and angular distributions become exceedingly narrow with Δv/v≲1% and Δϑ≲1  mrad. Optical observations indicate that the beam consists of micron-sized droplets (N≳109  atoms). This new droplet source provides opportunities for novel experimental studies of superfluid behavior.

This publication has 27 references indexed in Scilit: