Evaluating an optical-flow-based registration algorithm for contrast-enhanced magnetic resonance imaging of the breast
Authors:
- A L MartelAMA L Martel
- M S FrohMFM S Froh
- K K BrockKBK K Brock
- D B PlewesDPD B Plewes
- D C BarberDBD C Barber
- 31 May 2007
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (13) , 3803-3816
Abstract
Dynamic contrast-enhanced magnetic resonance imaging studies of the breast are frequently degraded by patient motion. In order to correct for this, any registration algorithm must overcome two major challenges: the highly deformable nature of the breast itself and the need to remove changes in signal intensity due to patient motion whilst leaving potentially significant changes in signal intensity due to changes in contrast agent concentration unchanged. In this paper, we evaluate the use of a non-rigid registration method that uses optical flow equations to drive the displacement of a grid of control points. With conventional optical flow techniques it is assumed that changes in image intensity are solely due to motion, making it unsuitable for use with contrast-enhanced studies. The registration algorithm evaluated in this paper overcomes this problem by including an additional term to account for changes in image intensity. Studies simulating physiologically plausible deformations of the breast together with realistic changes in contrast-enhancement derived from patient studies demonstrate that the algorithm is capable of registering images to sub-voxel accuracy within minutes. This technique has now been successfully incorporated into a breast cancer screening protocol allowing registered images to be provided routinely to the radiologist immediately after the scanning session.Keywords
This publication has 27 references indexed in Scilit:
- Anisotropic multi-scale fluid registration: evaluation in magnetic resonance breast imagingPhysics in Medicine & Biology, 2005
- Assessment of rigid multi-modality image registration consistency using the multiple sub-volume registration (MSR) methodPhysics in Medicine & Biology, 2005
- Simultaneous Segmentation and Registration of Contrast-Enhanced Breast MRI2005
- Automatic segmentation of medical images using image registration: diagnostic and simulation applicationsJournal of Medical Engineering & Technology, 2005
- Invertibility and transitivity analysis for nonrigid image registrationJournal of Electronic Imaging, 2003
- Parametric Analysis of Breast MRIJournal of Computer Assisted Tomography, 2002
- Comparison and Evaluation of Rigid, Affine, and Nonrigid Registration of Breast MR ImagesJournal of Computer Assisted Tomography, 1999
- Predicting error in rigid-body point-based registrationIEEE Transactions on Medical Imaging, 1998
- A physics-based coordinate transformation for 3-D image matchingIEEE Transactions on Medical Imaging, 1997
- Registration of low resolution medical imagesPhysics in Medicine & Biology, 1992