Relationship between peripheral airway function and patient-reported outcomes in COPD: a cross-sectional study
Authors:
- Akane HarunaAHAkane Haruna
- Toru OgaTOToru Oga
- Shigeo MuroSMShigeo Muro
- Tadashi OharaTOTadashi Ohara
- Susumu SatoSSSusumu Sato
- Satoshi MarumoSMSatoshi Marumo
- Daisuke KinoseDKDaisuke Kinose
- Kunihiko TeradaKTKunihiko Terada
- Michiyoshi NishiokaMNMichiyoshi Nishioka
- Emiko OgawaEOEmiko Ogawa
- Yuma HoshinoYHYuma Hoshino
- Toyohiro HiraiTHToyohiro Hirai
Open Access
- 7 March 2010
- journal article
- Published by Springer Nature in BMC Pulmonary Medicine
- Vol. 10 (1) , 10
Abstract
Background: Health status, dyspnea and psychological status are important clinical outcomes in chronic obstructive pulmonary disease (COPD). However, forced expiratory volume in one second (FEV1) measured by spirometry, the standard measurement of airflow limitation, has only a weak relationship with these outcomes in COPD. Recently, in addition to spirometry, impulse oscillometry (IOS) measuring lung resistance (R) and reactance (X) is increasingly being used to assess pulmonary functional impairment. Methods: We aimed to identify relationships between IOS measurements and patient-reported outcomes in 65 outpatients with stable COPD. We performed pulmonary function testing, IOS, high-resolution computed tomography (CT), and assessment of health status using the St. George's Respiratory Questionnaire (SGRQ), dyspnea using the Medical Research Council (MRC) scale and psychological status using the Hospital Anxiety and Depression Scale (HADS). We then investigated the relationships between these parameters. For the IOS measurements, we used lung resistance at 5 and 20 Hz (R5 and R20, respectively) and reactance at 5 Hz (X5). Because R5 and R20 are regarded as reflecting total and proximal airway resistance, respectively, the fall in resistance from R5 to R20 (R5-R20) was used as a surrogate for the resistance of peripheral airways. X5 was also considered to represent peripheral airway abnormalities. Results: R5-R20 and X5 were significantly correlated with the SGRQ and the MRC. These correlation coefficients were greater than when using other objective measurements of pulmonary function, R20 on the IOS and CT instead of R5-R20 and X5. Multiple regression analyses showed that R5-R20 or X5 most significantly accounted for the SGRQ and MRC scores. Conclusions: IOS measurements, especially indices of peripheral airway function, are significantly correlated with health status and dyspnea in patients with COPD. Therefore, in addition to its simplicity and non-invasiveness, IOS may be a useful clinical tool not only for detecting pulmonary functional impairment, but also to some extent at least estimating the patient's quality of daily life and well-being.Keywords
This publication has 43 references indexed in Scilit:
- The use of plethysmography and oscillometry to compare long‐acting bronchodilators in patients with COPDBritish Journal of Clinical Pharmacology, 2007
- Survival after Lung Volume Reduction in Chronic Obstructive Pulmonary DiseaseAmerican Journal of Respiratory and Critical Care Medicine, 2007
- The relationship between inflammatory markers and disability in chronic obstructive pulmonary disease (COPD)Primary Care Respiratory Journal, 2007
- Comparison of the effects of salmeterol/fluticasone propionate with fluticasone propionate on airway physiology in adults with mild persistent asthmaRespiratory Research, 2007
- Characterisation of phenotypes based on severity of emphysema in chronic obstructive pulmonary diseaseThorax, 2007
- Association between markers of emphysema and more severe chronic obstructive pulmonary diseaseThorax, 2006
- Measuring bronchodilation in COPD clinical trialsBritish Journal of Clinical Pharmacology, 2005
- The Nature of Small-Airway Obstruction in Chronic Obstructive Pulmonary DiseaseNew England Journal of Medicine, 2004
- Health status measurement in chronic obstructive pulmonary diseaseThorax, 2001
- The Hospital Anxiety and Depression ScaleActa Psychiatrica Scandinavica, 1983