Automated visual acuity estimation by optokinetic nystagmus using a stepped sweep stimulus
Preprint
Abstract
Purpose: Measuring visual acuity (VA) can be challenging in adults with cognitive impairment and young children. We developed an automatic system for measuring VA using Optokinetic Nystagmus (OKN). Methods: VA-OKN and VA by ETDRS (VA-ETDRS) were measured monocularly in healthy participants (n=23, age 30±12). VA was classified as reduced (n=22, >0.2 logMAR) or not (n=24, ≤0.2 logMAR) in each eye. VA-OKN stimulus was an array of drifting (5 deg/sec) vanishing disks presented in descending/ascending size order (0.0 to 1.0 logMAR in 0.1 logMAR steps). The stimulus was stepped every 2 seconds, and 10 sweeps were shown per eye. Eye tracking data determined when OKN activity ceased (descending sweep) or began (ascending sweep) to give an automated sweep VA. Sweep traces were randomized and assessed by a reviewer blinded to VA-ETDRS. A final per sweep VA and VA-OKN was thereby determined. Results: A single randomly selected eye was used for analysis. VA deficit group: There was no significant difference between overall mean VA-OKN and VA-ETDRS (p>0.05, paired t-test) and the r 2 statistic was 0.84. The 95% limits of agreement were 0.19 logMAR. No VA deficit group: There was a 0.24 logMAR bias between VA-OKN and VA-ETDRS and no correlation was found (r 2 = 0.06). However, the overall sensitivity/specificity for classification was 100%. Conclusions: A robust correlation between VA-ETDRS and VA-OKN was found. The method correctly detected a VA deficit. Translational relevance: OKN is a promising method for measuring VA in cognitively impaired adults and pre-verbal children.Keywords
This publication has 33 references indexed in Scilit:
- VEP estimation of visual acuity: a systematic reviewDocumenta Ophthalmologica, 2020
- A Real-Time Eye Tracking Method for Detecting Optokinetic Nystagmus2020
- Evaluation of the “Freiburg Acuity VEP” on Commercial EquipmentDocumenta Ophthalmologica, 2019
- The optokinetic response is effective to assess objective visual acuity in patients with cataract and age-related macular degenerationInternational Ophthalmology, 2018
- A novel and cheap method to correlate subjective and objective visual acuity by using the optokinetic responseInternational Ophthalmology, 2017
- A method for detecting optokinetic nystagmus based on the optic flow of the limbusVision Research, 2014
- Measurement of distance objective visual acuity with the computerized optokinetic nystagmus test in patients with ocular diseasesGraefe's Archive for Clinical and Experimental Ophthalmology, 2011
- Objective Measurement of Visual Acuity by Optokinetic Response Determination in Patients With Ocular DiseasesAmerican Journal of Ophthalmology, 2006
- Vanishing OptotypesArchives of Ophthalmology (1950), 1986
- Standardization of Objective Visual Acuity MeasurementsA.M.A. Archives of Ophthalmology, 1958