Six-degree-of-freedom Localization Under Multiple Permanent Magnets Actuation
Authors:
- Tomas da VeigaTVTomas da Veiga
- Giovanni PittiglioGPGiovanni Pittiglio
- Michael BrockdorffMBMichael Brockdorff
- James H. ChandlerJCJames H. Chandler
- Pietro ValdastriPVPietro Valdastri
Preprint
Abstract
Localization of magnetically actuated medical robots is essential for accurate actuation, closed loop control and delivery of functionality. Despite extensive progress in the use of magnetic field and inertial measurements for pose estimation, these have been either under single external permanent magnet actuation or coil systems. With the advent of new magnetic actuation systems comprised of multiple external permanent magnets for increased control and manipulability, new localization techniques are necessary to account for and leverage the additional magnetic field sources. In this letter, we introduce a novel magnetic localization technique in the Special Euclidean Group SE(3) for multiple external permanent magnetic field actuation and control systems. The method relies on a milli-meter scale three-dimensional accelerometer and a three-dimensional magnetic field sensor and is able to estimate the full 6 degree-of-freedom pose without any prior pose information. We demonstrated the localization system with two external permanent magnets and achieved localization errors of 8.5 ? 2.4 mm in position norm and 3.7 ? 3.6? in orientation, across a cubic workspace with 20 cm length.Keywords
All Related Versions
This publication has 27 references indexed in Scilit:
- Patient-Specific Magnetic Catheters for Atraumatic Autonomous EndoscopySoft Robotics, 2022
- Magnetically Actuated Medical Robots: An in vivo PerspectiveProceedings of the IEEE, 2022
- 2D Magnetic Actuation and Localization of a Surface Milli-Roller in Low Reynolds NumbersIEEE Robotics and Automation Letters, 2022
- Six-Degree-of-Freedom Localization With a 3-Axis Accelerometer and a 2-Axis Magnetometer for Magnetic Capsule EndoscopyIEEE Robotics and Automation Letters, 2022
- Medical Imaging of Microrobots: Toward In Vivo ApplicationsACS Nano, 2020
- Adaptive Dynamic Control for Magnetically Actuated Medical RobotsIEEE Robotics and Automation Letters, 2019
- Magnetic localization and control of helical robots for clearing superficial blood clotsAPL Bioengineering, 2019
- A Novel Passive Magnetic Localization Wearable System for Wireless Capsule EndoscopyIEEE Sensors Journal, 2019
- Small-scale soft-bodied robot with multimodal locomotionNature, 2018
- Six-Degree-of-Freedom Localization of an Untethered Magnetic Capsule Using a Single Rotating Magnetic DipoleIEEE Robotics and Automation Letters, 2016