Comparison of three immunological tests for seroepidemiological purposes in human echinococcosis
Authors:
- 1 September 1981
- journal article
- research article
- Published by Wiley in Parasite Immunology
- Vol. 3 (3) , 191-199
Abstract
The comparative sensitivity and specificity of three immunodiagnostic tests for hydatid disease--the latex agglutination (LA) test, the indirect haemagglutination (IHA) test and the counterimmunoelectrophoresis (CIEP) test--were studied. The results of the IHA test were evaluated using three positivity criteria. Antigen from the same source--hydatid cyst fluid pool of ovine origin--was utilized for the three tests. A total of 123 sera were studied; 30 preoperative sera from patients with other parasitic and infectious diseases, 30 sera from patients with non-parasitic diseases and 30 sera from normal blood donors. The results of the three tests were correlated to the immunoelectrophoresis (IEP) test based on the presence of arc 5. The same sensitivity (86.7%) and specificity (99%) was obtained in LA, CIEP and IHA tests when the minimum cross-reactivity titre criterion was employed for the latter. Non-specificity was relatively high (13%) in the IHA test when only serological reactivity was considered. The sensitivity of the IHA test decreased (83.3%) using the diagnostic titre criterion and non-specific reactions were eliminated. All three tests correlated well with the IEP test.Keywords
This publication has 11 references indexed in Scilit:
- Seroepidemiology of Parasitic DiseasesAnnual Review of Microbiology, 1978
- Further Observations on the Specificity of Antigen 5 of Echinococcus granulosusJournal of Parasitology, 1977
- Detection of the Echinococcus granulosus diagnostic arc 5 in sera from patients with surgically-confirmed E. multilocularis infectionParasitology Research, 1977
- Evaluation of Immunodiagnostic Techniques for the Detection of Human Hydatid Cyst Carriers in Field Studies *The American Journal of Tropical Medicine and Hygiene, 1976
- Echinococcosis in Arizona and New MexicoThe American Journal of Tropical Medicine and Hygiene, 1976
- Comparative Sensitivity and Specificity of the Casoni Intradermal and the Immunoelectrophoresis Tests for the Diagnosis of Hydatid DiseaseThe American Journal of Tropical Medicine and Hygiene, 1975
- Evaluation of Three Immunodiagnostic Tests for Human Hydatid DiseaseThe American Journal of Tropical Medicine and Hygiene, 1975
- Evaluation of Four Variants of the Indirect Hemagglutination Test for Human Hydatidosis *The American Journal of Tropical Medicine and Hygiene, 1975
- EPIDEMIOLOGY OF HYDATID DISEASE IN SOUTHERN ARGENTINAThe American Journal of Tropical Medicine and Hygiene, 1973
- An evaluation of the Casoni test in human hydatidosis using an antigen solution of low nitrogen concentrationTransactions of the Royal Society of Tropical Medicine and Hygiene, 1972