Abstract
Background:  Patients suffering head trauma are at high risk of having a concomitant cervical spine injury. A rigid cervical collar is usually applied to each patient until spinal stability is confirmed. Hard collars potentially cause venous outflow obstruction and are a nociceptive stimulus, which might elevate intracranial pressure (ICP). This study tested the hypothesis that application of a hard collar is associated with an increase in ICP.Methods:  A prospective series of 10 head‐injured patients with a postresuscitation Glasgow coma scale score of nine or less had ICP measurements before and after cervical hard collar application.Results:  Nine out of 10 patients had a rise in ICP following application of the collar. The difference in pre‐ and postapplication ICP was statistically significant (P < 0.05).Conclusions:  Early assessment of the cervical spine in head‐injured patients is recommended to minimize the risk of intracranial hypertension related to prolonged cervical spine immobilization with a hard collar.