Quantification of SARS-CoV-2 in wastewater v2

Authors:
  • DWDavid Ian Walker
    David Ian Walker
  • JLJames Lowther
    James Lowther
  • NENick Evens
    Nick Evens
  • JWJonathan Warren
    Jonathan Warren
  • JPJonathan Porter
    Jonathan Porter
  • KFKata Farkas
    Kata Farkas
  • DJDavey Jones
    Davey Jones

Abstract
This procedure describes the concentration and quantification of SARS-CoV-2 from wastewater as used by the Environmental Monitoring for Health Protection (EMHP) in England programme during the COVID-19 pandemic. It is based on the standard operating procedure developed by a collaboration between Environment Agency National Laboratory Service and Bangor University. This generic protocol was prepared by Cefas to allow laboratories to carry out SARS-CoV-2 quantification from wastewater samples in a way that is similar to the EA’s procedure, while still allowing some variation where necessary. Viral concentration is by ammonium sulphate precipitation followed by centrifugation. Viral RNA extraction is by lysis with guanidine isothiocyanate (GITC) and adsorption to silica. Extracted viral RNA is amplified and detected by quantitative RT-PCR (RT-qPCR). This protocol describes a method for quantification of virus RNA in the test sample and includes production of control materials. The wastewater samples are first clarified by centrifugation. A precipitant (ammonium sulphate) is then added before the sample is incubated for 1 hour at 4°C. This is followed by centrifugation to generate a viral pellet that is suitable for viral nucleic acid extraction. Details of addition of a spike process control (phi6) to the test samples are also described. It is necessary to extract RNA using a method that yields clean RNA preparations to reduce the effect of PCR inhibitors. In this protocol the chaotropic agent GITC is used to disrupt the viral capsid. RNA is then adsorbed to silica to assist purification through several washing stages. Purified viral RNA is released from the silica into a buffer prior to RT-qPCR. The use of the Thermofisher KingFisher Flex Purification System with BioMerieux’s NucliSENS extraction reagents is described here. Other RNA extraction methods that use GITC followed by silica-based purification may also be applicable if they can be demonstrated to give equivalent results. This protocol uses one-step RT-qPCR using hydrolysis probes. In one-step RT-qPCR, reverse transcription and PCR amplification are carried out consecutively in the same tube. Hydrolysis probe-based qPCR utilises a short DNA probe with a fluorescent label and a fluorescence quencher attached at opposite ends. The assay chemistry ensures that as the quantity of amplified product increases, the probe is broken down, and the fluorescent signal from the label increases proportionately. Fluorescence may be measured at each stage throughout the cycle. The first point in the PCR cycle at which amplification can be detected for any reaction is proportional to the quantity of template, therefore analysis of the fluorescence plots enables determination of the quantity of target sequence in the sample.