Evaluation of Dentaport ZX and Raypex 6 electronic apex locators: An in vivo study
Open Access
- 1 January 2014
- journal article
- research article
- Published by Medicina Oral, S.L. in Medicina Oral Patología Oral y Cirugia Bucal
- Vol. 19 (2) , e202-e205
Abstract
Introduction: Raypex 6 is an electronic apex locator (EAL) that has not yet been tested in vivo. The purpose of this in vivo study was to compare the accuracy of two EALs: the Dentaport ZX and the Raypex 6. Material and Methods: The study involved 36 straight single-rooted teeth. A 10-K file was advanced until the EAL detected the major foramen. The file was fixed in a replaceable pattern of light-cured composite. The apical part of each canal was trimmed to expose the file tip. The distances from the file tips to the major foramen were measured. Results: Wilcoxon’s signed Rank test found no significant differences between the Dentaport ZX and Raypex 6 in terms of their abilities to detect the major foramen (P = .52) The Dentaport ZX was accurate 82.35% of the time to ± 0.5 mm and 97.05% of the time to ± 1 mm, whereas the Raypex 6 was accurate 88.22% of the time to ± 0.5 mm and 100% of the time to ± 1 mm. Conclusions: No statistically significant differences were observed between the performance of the Dentaport ZX and Raypex 6 EALs under the in vivo clinical conditions used in this study.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of In Vivo and In Vitro Readings When Testing the Accuracy of the Root ZX Apex LocatorJournal of Endodontics, 2012
- Clinical Accuracy of a New Apex Locator with an Automatic Compensation CircuitJournal of Endodontics, 2002
- The Influence of Sodium Hypochlorite Irrigation on the Accuracy of the Root ZX Electronic Apex LocatorJournal of Endodontics, 2002
- The Ability of Root ZX Apex Locator to Reduce the Frequency of Overestimated Radiographic Working lengthJournal of Endodontics, 2002
- Methodological considerations in the determination of working lengthInternational Endodontic Journal, 2001
- A SEM study of in vivo accuracy of the Root ZX electronic apex locatorJournal of Endodontics, 1998
- New electronic canal measuring device based on the ratio methodJournal of Endodontics, 1994
- The influence of the major and minor foramen diameters on apical electronic probe measurementsJournal of Endodontics, 1990
- Factors affecting the long-term results of endodontic treatmentJournal of Endodontics, 1990
- The position and topography of the apical canal constriction and apical foramenInternational Endodontic Journal, 1984