Success and Failure Rates of 9 mm or Shorter Implants in the Replacement of Missing Maxillary Molars When Restored with Individual Crowns: Preliminary Results 0 to 84 Months in Function. A Retrospective Study
Authors:
- Paul A. FugazzottoPFPaul A. Fugazzotto
- Jay R. BeagleJBJay R. Beagle
- Jeffrey GanelesJGJeffrey Ganeles
- Robert JaffinRJRobert Jaffin
- James VlassisJVJames Vlassis
- Akshay KumarAKAkshay Kumar
- 1 February 2004
- journal article
- Published by Wiley in Journal of Periodontology
- Vol. 75 (2) , 327-332
Abstract
Background: The ability to utilize shorter implants in the reconstruction of the posterior maxilla would, theoretically, simplify therapy by lessening the need for augmentation surgery. The purpose of this retrospective study was to assess the success and failure rates of ≤9 mm or shorter implants in the maxillary posterior regions restored with individual crowns.Methods: A total of 979 implants were placed in maxillary molar positions and restored with individual crowns. The implants were followed in function for up to 84 months. The results are discussed in terms of clinical applicability and indications for use.Results: The cumulative success rates in function were 94.5% for implants in the maxillary first molar positions and 98.7% for implants in the maxillary second molar positions, yielding an overall cumulative success rate of 95.1%, in function for up to 84 months.Conclusion: These findings suggest that non‐countersunk implants of 7 to 9 mm in length may be successfully restored with single crowns in the maxillary molar region. J Periodontol 2004;75:327‐332.Keywords
This publication has 9 references indexed in Scilit:
- Augmentation of the Posterior Maxilla: A Proposed Hierarchy of Treatment SelectionJournal of Periodontology, 2003
- Implant Survival to 36 Months as Related to Length and DiameterAnnals of Periodontology, 2000
- Crestal Bone Changes Around Titanium Implants. A Histometric Evaluation of Unloaded Non‐Submerged and Submerged Implants in the Canine MandibleJournal of Periodontology, 2000
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997
- Retrospective multicenter analysis of 3i endosseous dental implants placed over a five‐year periodClinical Oral Implants Research, 1996
- Experience with ITI osseointegrated implants at five centres in the UKBritish Journal of Oral and Maxillofacial Surgery, 1992
- Fixture design and overload influence marginal bone loss and future success in the Brånemark® systemClinical Oral Implants Research, 1992
- Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigsJournal of Biomedical Materials Research, 1991
- The Excessive Loss of Branemark Fixtures in Type IV Bone: A 5‐Year AnalysisJournal of Periodontology, 1991