Feasibility, safety, and economic consequences of using minimal flow anaesthesia by Maquet FLOW-i equipped with automated gas control
Authors:
Open Access
- 8 October 2021
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-6
Abstract
Low fresh gas flow rates are recommended because of their benefits, however, its use is limited due to associated risks. The main purpose of this study was to investigate whether 300 mL of fresh gas flow that practised with automated gas control mode is applicable and safe. The second aim is to show that automated mode can provide economic benefits. Sixty hepatectomy cases who suitable criterias were included to cohort study in three groups as prospective, sequential, observational. An operating room were allocated only for this study. 300 mL fresh gas flow with automated mode (groupA3), 600 mL fresh gas flow with automated mode (groupA6) and, 600 mL fresh gas flow with manually (groupM6) was applied. Patients’ respiratory, hemodynamic parameters (safety), number of setting changes, O2concentration in the flowmeter that maintained FiO2:0.4 during the low flow anaesthesia (feasibility) and comsumption data of anaesthetic agent and CO2absorber (economical) were collected and compared. p < 0.05 was accepted as statistical significance level. No significant differences were detected between the groups in terms of demographic data and duration of operation. Safety datas (hemodynamic, respiratory, and tissue perfusion parameters) were within normal limits in all patients. O2concentration in the flowmeter that maintained FiO2:0.4 was statistically higher in groupA3 (92%) than other groups (p < 0.001) but it was still within applicable limits (below the 100%). Number of setting changes was statistically higher in groupM6 than other groups (p < 0.001). The anaesthetic agent consumption was statistically less in groupA3 (p = 0.018). We performed fresh gas flow of 300 mL by automated mode without deviating from the safety limits and reduced the consumption of anaesthetic agent. We were able to maintain FiO2:0.4 in hepatectomies without much setting changes, and we think that the automated mode is better in terms of ease of practise.Keywords
This publication has 14 references indexed in Scilit:
- Automated gas control with the Maquet FLOW-iJournal of Clinical Monitoring and Computing, 2015
- Reducing Wastage of Inhalation Anesthetics Using Real-time Decision Support to Notify of Excessive Fresh Gas FlowAnesthesiology, 2013
- Inhalational anaesthesia with low fresh gas flowIndian Journal of Anaesthesia, 2013
- Brief review: Theory and practice of minimal fresh gas flow anesthesiaCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 2012
- Life Cycle Greenhouse Gas Emissions of Anesthetic DrugsAnesthesia & Analgesia, 2012
- Managing Fresh Gas Flow to Reduce Environmental ContaminationAnesthesia & Analgesia, 2012
- Oxygen and anesthesia: what lung do we deliver to the post‐operative ward?Acta Anaesthesiologica Scandinavica, 2012
- A survey of obstetric complications and pregnancy outcomes in paediatric and nonpaediatric anaesthesiologistsPediatric Anesthesia, 2003
- Low-Flow AnaesthesiaPharmacoEconomics, 2000
- Low‐flow anaesthesiaAnaesthesia, 1995