Investigation of respiration induced intra- and inter-fractional tumour motion using a standard Cone Beam CT
Open Access
- 13 September 2010
- journal article
- research article
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 49 (7) , 1192-1198
Abstract
Background. To investigate whether a standard Cone beam CT (CBCT) scan can be used to determined the intra- and inter-fractional tumour motion for lung tumours that have infiltrated the mediastinum. Material and methods. This study includes 23 patients with non small cell lung cancer (NSCLC). The intra-fractional tumour motion was analysed for each patient on a 4D-CT scan as well as on three 4D-CBCT (fraction 3, 10 and 20). The 4D-CBCT was reconstructed from a standard 3D-CBCT using in-house developed software. The tumour (GTV) was delineated in the first phase of the 4D-CT. Registration of phase one from the 4D-CT and 4D-CBCT was used to copy the GTV to the CBCT scans. Hereafter the motion of the outlined GTV was tracked in the planning 4D-CT and the three 4D-CBCT using Pinnacle® version 8.1w (research version). Additionally, the inter-fractional tumour movement, relative to the bony structure, was obtained from the difference in tumour position between the 3D-CT and the standard 3D-CBCT. Results. It is possible to track a lung tumour with mediastinal infiltration in the 4D-CBCT scan based on a standard 3D-CBCT. The respiration motion in the 4D-CBCT is not significantly different from the result found from the initial 4D-CT. Likewise, no differences in respiration motion was found between fractions 3, 10 and 20. Conclusion. This study shows that it is possible to track tumour motion for NSCLC patients with mediastinal infiltration using a standard 3D-CBCT. No change in the intra-fractional tumour motion of clinically relevance was observed during the fractionated treatment course. The inter-fractional tumour motion found underlines the importance of using daily IGRT with online match on soft tissue in order to be able to reduce treatment margins.Keywords
This publication has 16 references indexed in Scilit:
- Variability of Four-Dimensional Computed Tomography Patient ModelsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Acceleration and validation of optical flow based deformable registration for image-guided radiotherapyActa Oncologica, 2008
- The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)Medical Physics, 2006
- Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patientsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- 4D imaging for target definition in stereotactic radiotherapy for lung cancerActa Oncologica, 2006
- Respiratory correlated cone beam CTMedical Physics, 2005
- Four‐dimensional computed tomography: Image formation and clinical protocolMedical Physics, 2005
- 4-dimensional computed tomography imaging and treatment planningSeminars in Radiation Oncology, 2004
- Artifacts in computed tomography scanning of moving objectsSeminars in Radiation Oncology, 2004
- Planning target volumes for radiotherapy: how much margin is needed?International Journal of Radiation Oncology - Biology - Physics (IJROBP), 1999