X-Ray Measurement of Long-Range Order in β-AgZn
Author:
- 1 May 1951
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 22 (5) , 663-665
Abstract
The replacement of small amounts of Ag by Au in AgZn raises the critical temperature for long‐range ordering and completely suppresses the zeta‐phase. Measurements of Tc were made in a high temperature camera using several percentages of Au. Extrapolation to zero content of Au gives Tc=272°C for pure AgZn. The variation of long‐range order with temperature was determined from measurements of the integrated intensity of the (111) superstructure line, using a compact of filings of composition 3.5 Au, 46.5 Ag, and 50.0 Zn. The variation is similar to that found in β‐brass, and is in agreement with the predictions of the Cowley theory.Keywords
This publication has 5 references indexed in Scilit:
- X-Ray Measurement of Long Range Order in β-BrassJournal of Applied Physics, 1950
- An Approximate Theory of Order in AlloysPhysical Review B, 1950
- The equilibrium diagram of the system silver-zincProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1941
- An X-ray study of the superlattice in certain alloysProceedings of the Physical Society (1926-1948), 1938
- The effect of thermal agitation on atomic arrangement in alloysProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1934