Dose and slice thickness evaluation with nMAG gel dosimeters in computed tomography
Authors:
Open Access
- 8 February 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 2632
Abstract
Computed tomography (CT) has been widely used in clinical diagnosis. It is important to estimate radiation dose and perform image quality assurance procedures for CT scans. In this study, nMAG gel dosimeters were used to simultaneously measure the 300-mm weighted CT dose index (CTDI) and slice sensitivity profile (SSP) for multiple detector CT (MDCT). Magnetic resonance imaging (MRI) was performed on the irradiated gel to create R2‒dose response curves for the tube voltages of 120 and 140 kVp. The gel dosimeters were loaded in three home-made cylindrical phantoms to obtain CTDI100 and CTDI300. The full width at half maximum (FWHM) for 2, 5, 10, 14.4, and 38.4-mm slice thicknesses was measured and compared with the result obtained by radiochromic films. The difference in weighted CTDI100 obtained by the gel dosimeter and ionization chamber was less than 1%. The CTDI efficiency at 120 and 140 kVp was in the range of 80.1%–82.5%. The FWHM of SSP measured by the gel dosimeter matched very well with the nominal slice thickness. The use of nMAG gel dosimeters combined with the home-made cylindrical phantoms can provide 300-mm weighted CTDI and slice thickness information, showing potential for quality assurance and clinical applications in MDCT.Keywords
This publication has 29 references indexed in Scilit:
- The impact of x-ray tube stabilization on localized radiation dose in axial CT scans: initial results in CTDI phantomsPhysics in Medicine & Biology, 2016
- CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risksLa radiologia medica, 2014
- How to Estimate Multislice CT Effective Dose More CorrectlyHealth Physics, 2013
- The feasibility of a regional CTDIvol to estimate organ dose from tube current modulated CT examsMedical Physics, 2013
- Intercomparison of patient CTDI surveys in three countriesRadiation Protection Dosimetry, 2012
- Estimation of the weighted CTDI∞for multislice CT examinationsMedical Physics, 2012
- NCRP REPORT NO. 160, IONIZING RADIATION EXPOSURE OF THE POPULATION OF THE UNITED STATES, MEDICAL EXPOSURE—ARE WE DOING LESS WITH MORE, AND IS THERE A ROLE FOR HEALTH PHYSICISTS?Health Physics, 2009
- Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scannerPhysics in Medicine & Biology, 2009
- Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scannerBritish Journal of Radiology, 2006
- Radiation dose in Spiral CT: The relative effects of collimation and pitchMedical Physics, 1999