The use of photoplethysmography for assessing hypertension
Top Cited Papers
Open Access
- 26 June 2019
- journal article
- review article
- Published by Springer Nature in npj Digital Medicine
- Vol. 2 (1) , 1-11
Abstract
The measurement of blood pressure (BP) is critical to the treatment and management of many medical conditions. High blood pressure is associated with many chronic disease conditions, and is a major source of mortality and morbidity around the world. For outpatient care as well as general health monitoring, there is great interest in being able to accurately and frequently measure BP outside of a clinical setting, using mobile or wearable devices. One possible solution is photoplethysmography (PPG), which is most commonly used in pulse oximetry in clinical settings for measuring oxygen saturation. PPG technology is becoming more readily available, inexpensive, convenient, and easily integrated into portable devices. Recent advances include the development of smartphones and wearable devices that collect pulse oximeter signals. In this article, we review (i) the state-of-the-art and the literature related to PPG signals collected by pulse oximeters, (ii) various theoretical approaches that have been adopted in PPG BP measurement studies, and (iii) the potential of PPG measurement devices as a wearable application. Past studies on changes in PPG signals and BP are highlighted, and the correlation between PPG signals and BP are discussed. We also review the combined use of features extracted from PPG and other physiological signals in estimating BP. Although the technology is not yet mature, it is anticipated that in the near future, accurate, continuous BP measurements may be available from mobile and wearable devices given their vast potential.Keywords
This publication has 80 references indexed in Scilit:
- Implementation of the World Health Organization Surgical Safety Checklist, Including Introduction of Pulse Oximetry, in a Resource-Limited SettingAnnals of Surgery, 2013
- Noninvasive cuffless blood pressure estimation using pulse transit time and Hilbert–Huang transformComputers and Electrical Engineering, 2013
- Wireless Body Area Networks for Healthcare: A SurveyInternational Journal of Ad hoc, Sensor & Ubiquitous Computing, 2012
- Multiparameter Intelligent Monitoring in Intensive Care II: A public-access intensive care unit database*Critical Care Medicine, 2011
- Relations between ac-dc components and optical path length in photoplethysmographyJournal of Biomedical Optics, 2011
- Enhancing the estimation of blood pressure using pulse arrival time and two confounding factorsPhysiological Measurement, 2009
- Analysis of the Effect of Ageing on Rising Edge Characteristics of the Photoplethysmogram using a Modified Windkessel ModelCardiovascular Engineering, 2007
- Smart Vest: Wearable multi-parameter remote physiological monitoring systemMedical Engineering & Physics, 2007
- Evaluation of blood pressure changes using vascular transit timePhysiological Measurement, 2006
- Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nmJournal of Physics D: Applied Physics, 2005