Development and Validation for the Simultaneous Estimation of Rilpivirine and Dolutegravir in Bulk and Pharmaceutical Dosage Forms by RP-HPLC Method
Authors:
- 24 November 2022
- journal article
- research article
- Published by A and V Publications in Research Journal of Pharmacy and Technology
- Vol. 15 (11) , 5302-5306
Abstract
Background: A simple new novel, accurate, robust and precise RP-HPLC method was developed and validated for the simultaneous quantification of Rilpivirine and Dolutegravir in bulk and marketed tablet formulations. Methods: The method development was carried out by using INERTSIL ODS column (250×4.6mm, 5µm), by isocratic approach using a mixture of Phosphate Buffer (pH 6.8): Acetonitrile in the ratio of (35: 65) as mobile phase. The flow rate was 1.0 ml/min, 259 nm as detection wavelength. Results: The retention time of 3.285 min was observed for Dolutegravir and 4.635 min for Rilpivirine. Dolutegravir percentage purity was 99.97% and 100.63% for Rilpivirine. The system suitability parameters such as theoretical plate and tailing factor for Dolutegravir and Rilpivirine was observed in the range of 3209, 1.13 and 5210, 1.11and was found to be within the limit. The linear was observed in the concentration ranges of 50µg – 250µg for Dolutegravir and 30µg - 150µg for Rilpivirine and correlation coefficient (r2) value for Dolutegravir was 0.999 and 0.999 for Rilpivirine. The percentage RSD for repeatability was observed to be within the acceptance limit 0.1 and 0.7. The percentage RSD for intermediate precision was 0.4 and 0.8. The precision study was precise, robust, and repeatable. The LOD values were 3 and 3.02 and LOQ values were 9.98 and 10.01. Conclusion: Hence the optimized RP-HPLC method can be used for simultaneous quantification and concurrent analysis of Dolutegravir and Rilpivirine in API and combined dosage formulations.Keywords
This publication has 19 references indexed in Scilit:
- Development and Validation of a Chromatographic Ultraviolet Method for the Simultaneous Quantification of Dolutegravir and Rilpivirine in Human PlasmaTherapeutic Drug Monitoring, 2016
- High-Performance Liquid Chromatographic and High-Performance Thin-Layer Chromatographic Method for Quantitative Estimation of Dolutegravir Sodium in Bulk Drug and Pharmaceutical Dosage FormScientia Pharmaceutica, 2016
- A liquid chromatography–tandem mass spectrometry assay for quantification of rilpivirine and dolutegravir in human plasmaJournal of Chromatography B, 2014
- Stability-Indicating HPLC Method for the Simultaneous Determination of HIV Tablet Containing Emtricitabine, Tenofovir Disoproxil Fumarate, and Rilpivirine Hydrochloride in Pharmaceutical Dosage FormsInternational Scholarly Research Notices, 2014
- Dolutegravir, the Second-Generation of Integrase Strand Transfer Inhibitors (INSTIs) for the Treatment of HIVInfectious Diseases and Therapy, 2014
- An update on clinical utility of rilpivirine in the management of HIV infection in treatment-naïve patientsHIV/AIDS - Research and Palliative Care, 2013
- Non‐nucleoside reverse transcriptase inhibitors: a review on pharmacokinetics, pharmacodynamics, safety and tolerabilityJournal of the International AIDS Society, 2013
- Structural and Functional Analyses of the Second-Generation Integrase Strand Transfer Inhibitor Dolutegravir (S/GSK1349572)Molecular Pharmacology, 2011
- Safety, efficacy, and pharmacokinetics of rilpivirine: systematic review with an emphasis on resource-limited settingsHIV/AIDS - Research and Palliative Care, 2011
- Pharmacokinetics and Safety of S/GSK1349572, a Next-Generation HIV Integrase Inhibitor, in Healthy VolunteersAntimicrobial Agents and Chemotherapy, 2010