Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plans
Open Access
- 1 January 2016
- journal article
- research article
- Published by Medknow in Journal of Medical Physics
- Vol. 41 (3) , 192-7
Abstract
Recently, Eclipse treatment planning system (TPS) version 8.8 was upgraded to the latest version 13.6. It is customary that the vendor gives training on how to upgrade the existing software to the new version. However, the customer is provided less inner details about changes in the new software version. According to manufacturer, accuracy of point dose calculations and irregular treatment planning is better in the new version (13.6) compared to the old version (8.8). Furthermore, the new version uses voxel-based calculations while the earlier version used point dose calculations. Major difference in intensity-modulated radiation therapy (IMRT) plans was observed between the two versions after re-optimization and re-calculations. However, minor difference was observed for IMRT cases after performing only re-calculations. It is recommended TPS quality assurance to be performed after any major upgrade of software. This can be done by performing dose calculation comparisons in TPS. To assess the difference between the versions, 25 clinical cases from the old version were compared keeping all the patient data intact including the monitor units and comparing the differences in dose calculations using dose volume histogram (DVH) analysis. Along with DVH analysis, uniformity index, conformity index, homogeneity index, and dose spillage index were also compared for both versions. The results of comparative study are presented in this paper.Keywords
This publication has 16 references indexed in Scilit:
- The accuracy of the Acuros XB algorithm in external beam radiotherapy – a comprehensive reviewInternational Journal of Cancer Therapy and Oncology, 2014
- Homogeneity Index: An objective tool for assessment of conformal radiation treatmentsJournal of Medical Physics, 2012
- Feasibility of a Multigroup Deterministic Solution Method for Three-Dimensional Radiotherapy Dose CalculationsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- A dosimetric comparison of non-coplanar IMRT versus Helical Tomotherapy for nasal cavity and paranasal sinus cancerRadiotherapy and Oncology, 2007
- Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situationsPhysics in Medicine & Biology, 2006
- Dosimetric comparison of helical tomotherapy treatment and step-and-shoot intensity-modulated radiotherapy of retroperitoneal sarcomaRadiotherapy and Oncology, 2006
- Conformity index: A reviewInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Effectiveness of noncoplanar IMRT planning using a parallelized multiresolution beam angle optimization method for paranasal sinus carcinomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- A comparison of conformal and intensity-modulated techniques for oesophageal radiotherapyRadiotherapy and Oncology, 2001
- Volumetric and dosimetric evaluation of radiation treatment plans: radiation conformity indexInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1998