Estimation of effective doses from MDCT and CBCT imaging of extremities
Authors:
- 23 October 2018
- journal article
- research article
- Published by IOP Publishing in Journal of Radiological Protection
- Vol. 38 (4) , 1371-1383
Abstract
Little research has been published on the radiation burden of cone beam computed tomography (CBCT) in comparison with multi-row detector computed tomography (MDCT) for extremity imaging. This manuscript reports effective doses produced by standard and reduced dose imaging protocols for a 128-slice MDCT unit and a dedicated extremity imaging device using CBCT technology. Anthropomorphic phantoms with x-ray attenuation characteristics simulating adult hand-wrist, foot-ankle, and knee areas were modified to receive optically stimulated luminescent dosimeters (OSL). Standard and lower kVp reduced dose (Lite) exposures were compared. Effective doses for four age groups (five years old to adult) were calculated following 2007 recommendations of the ICRP. Standard CBCT imaging protocols produced effective doses (1.3–21.1 μ Sv) that were on the order of daily US ubiquitous background radiation doses. CBCT doses were on average 90% less than comparable MDCT views of the same anatomy (9.1–204 μ Sv). Child doses were significantly greater than adult doses ( p = 0.0001). CBCT doses could be further reduced by 36%–51% with Lite exposure protocols. These protocols can be recommended for children and in cases where increased image noise will not interfere with the diagnostic task.Keywords
This publication has 15 references indexed in Scilit:
- Effective Radiation Dose in the Wrist Resulting from a Radiographic Device, Two CBCT Devices and One MSCT Device: A Comparative StudyRadiation Protection Dosimetry, 2017
- Effective radiation dose of a MSCT, two CBCT and one conventional radiography device in the ankle regionJournal of Foot and Ankle Research, 2015
- Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemetersRadiation Protection Dosimetry, 2013
- Computational lymphatic node models in pediatric and adult hybrid phantoms for radiation dosimetryPhysics in Medicine & Biology, 2013
- PrefaceAnnals of the ICRP, 2009
- Body height estimation based on tibia length in different stature groupsAmerican Journal of Physical Anthropology, 2003
- The X‐ray attenuation characteristics and density of human calcaneal marrow do not change significantly during adulthoodJournal of Orthopaedic Research, 2002
- Predicting composition of leg sections with anthropometry and bioelectrical impedance analysis, using magnetic resonance imaging as referenceClinical Science, 1999
- Active bone marrow distribution as a function of age in humansPhysics in Medicine & Biology, 1981