Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets
Authors:
Open Access
- 31 October 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in European Journal of Orthodontics
- Vol. 36 (3) , 245-254
Abstract
The purpose of this study was to compare the activation and deactivation forces generated during first-order archwire deflections when different sizes and types of NiTi wires are paired with conventional and self-ligating brackets (SLBs) and to evaluate the rotational control between these same archwire and bracket combinations. Four maxillary premolar SLBs (Damon 3MX, SmartClip, Carriere, and In-Ovation R) and one conventional twin bracket (Victory) were paired with seven archwires [0.014, 0.016, 0.018, 0.016 × 0.022 Ultra Therm (thermal Af80-90°F), 0.016, 0.018 SPEED Supercable, and 0.017 × 0.025 Turbo]. A cantilever test design was used and 10 trials per bracket/archwire combination were performed. Load/deflection data were captured over 4 mm first-order archwire deflections. Forces generated were compared across all bracket/archwire combinations. Among thermal archwires, for a given deflection, forces increased with increasing archwire size. Supercable archwires displayed less force than their same size thermal counterparts. The Turbo archwire generated force values in between those of 0.016 and 0.018 thermal archwires. Rotational control improved with increasing wire dimensions and for a given archwire size. Rotational control among brackets generally ranked as follows: In-Ovation R > SmartClip > Carriere and Damon 3MX.Keywords
This publication has 9 references indexed in Scilit:
- Moments Generated during Simulated Rotational Correction with Self-Ligating and Conventional BracketsThe Angle Orthodontist, 2008
- Forces exerted by conventional and self-ligating brackets during simulated first- and second-order correctionsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2008
- Resistance to sliding of orthodontic brackets with bumps in the slot floors and walls: effects of second-order angulationDental Materials, 2004
- Comparison of resistance to sliding between different self-ligating brackets with second-order angulation in the dry and saliva statesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2002
- Treatment time, outcome, and patient satisfaction comparisons of Damon and conventional bracketsClinical Orthodontics and Research, 2001
- Resistance to sliding of self-ligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) statesAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2001
- Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for bindingEuropean Journal of Orthodontics, 1999
- The influence of bracket design on moment production during axial rotationAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1993
- Mechanics of tooth movementAmerican Journal of Orthodontics, 1984