Relationships between a proprietary index, bispectral index, and hemodynamic variables as a means for evaluating depth of anesthesia in dogs anesthetized with sevoflurane
Authors:
- María F. Martín CanchoMCMaría F. Martín Cancho
- Juan R. LimaJLJuan R. Lima
- Verónica CrisóstomoVCVerónica Crisóstomo
- Jesús Usón-GargalloJUJesús Usón-Gargallo
- Luis J. EzquerraLELuis J. Ezquerra
- 1 August 2004
- journal article
- research article
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 65 (8) , 1128-1135
Abstract
Objective —To evaluate relationships among various techniques for monitoring anesthetic depth in sevoflurane-anesthetized dogs undergoing orthopedic surgery. Animals —10 dogs. Procedure —Dogs were medicated with acepromazine (0.05 mg/kg, IM), buprenorphine (0.01 mg/kg, IM), and atropine (0.04 mg/kg, IM). Anesthesia was induced and maintained with sevoflurane. Cardiovascular and respiratory responses were monitored. Anesthetic depth was monitored by use of the bispectral index (BIS), and a proprietary index was used to monitor activity of the autonomic nervous system. Results —A significant decrease in BIS was seen after induction but concurrent changes were not observed for the other techniques. The proprietary index increased significantly after intubation, but no changes were seen for the other techniques. No significant changes were detected during incision or when higher nociceptive stimuli were applied. We did not identify a correlation between BIS and the proprietary index, the proprietary index and hemodynamic variables, or the BIS and hemodynamic variables during induction and maintenance. A significant increase in the proprietary index and BIS was detected at the time of resumption of reflexes. During anesthetic recovery, a correlation was found between the proprietary index and BIS but not between hemodynamic variables and the other techniques. Conclusions and Clinical Relevance —A significant increase in the proprietary index, but not the BIS or hemodynamic variables, was detected during intubation. Anesthetic induction with sevoflurane did not prevent the sympathetic stimulus attributable to tracheal intubation. Monitoring of hemodynamic variables does not provide sufficient information to allow clinicians to evaluate stress during anesthetic recovery. ( Am J Vet Res 2004;65:1128–1135)Keywords
This publication has 34 references indexed in Scilit:
- Bispectral index, spectral edge frequency 95%, and median frequency recorded for various concentrations of isoflurane and sevoflurane in pigsAmerican Journal of Veterinary Research, 2003
- Endocrine, haematological and metabolic responses to sevoflurane anaesthesia in lambsVeterinary Anaesthesia and Analgesia, 2001
- Bispectral Index Monitoring Allows Faster Emergence and Improved Recovery from Propofol, Alfentanil, and Nitrous Oxide AnesthesiaAnesthesiology, 1997
- Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced SedationAnesthesia & Analgesia, 1997
- Prediction of Movement Using Bispectral Electroencephalographic Analysis During Propofol/Alfentanil or Isoflurane/Alfentanil AnesthesiaAnesthesia & Analgesia, 1995
- Eeg bispectrum predicts movement during thiopental/isoflurane anesthesiaJournal of Clinical Monitoring and Computing, 1995
- Bispectral Analysis of the Electroencephalogram Correlates with Patient Movement to Skin Incision during Propofol/Nitrous Oxide AnesthesiaAnesthesiology, 1994
- An introduction to bispectral analysis for the electroencephalogramJournal of Clinical Monitoring and Computing, 1994
- Electroencephalographic Power Spectrum Analysis as a Monitor of Anesthetic Depth in HorsesVeterinary Surgery, 1991
- Power spectral analysis of heart rate and arterial pressure variabilities as a marker of sympatho-vagal interaction in man and conscious dog.Circulation Research, 1986