Phase II study comparing nasal pressure monitoring with capnography during invasive endoscopic procedures: a single-center, single-arm trial
Authors:
Open Access
- 23 January 2023
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-10
Abstract
Nasal pressure signal is commonly used to evaluate obstructive sleep apnea. This study aimed to assess its safety for respiratory monitoring during sedation. A total of 45 adult patients undergoing sedation with propofol and fentanyl for invasive endoscopic procedures were enrolled. While both nasal pressure and capnograph signals were continuously recorded, only the nasal pressure signal was displayed. The primary outcome was the incidence of oxygen desaturation below 90%. The secondary outcomes were the ability to predict the desaturation and incidence of harmful events and false alarms, defined as an apnea waveform lasting more than 3 min without desaturation. Of the 45 participants, 43 completed the study. At least one desaturation event occurred in 12 patients (27.9%; 95% confidence interval 15.3–43.7%). In these 12 patients, more than half of the desaturation events were predictable in 9 patients by capnography and 11 patients by nasal pressure monitoring (p = 0.59). In the 43 patients, false alarms were detected in 7 patients with capnography and 11 patients with nasal pressure monitoring (p = 0.427). Harmful events unrelated to nasal pressure monitoring occurred in 2 patients. Nasal pressure monitoring is safe and possibly useful for respiratory monitoring despite false alarms during sedation.Keywords
This publication has 31 references indexed in Scilit:
- The role of capnography in endoscopy patients undergoing nurse-administered propofol sedation: a randomized studyScandinavian Journal of Gastroenterology, 2013
- Hypoxemia during Moderate Sedation for Gastrointestinal Endoscopy: Causes and AssociationsDigestion, 2011
- Incidence of Sedation-Related Complications With Propofol Use During Advanced Endoscopic ProceduresClinical Gastroenterology and Hepatology, 2010
- The risk and safety of anesthesia at remote locations: the US closed claims analysisCurrent Opinion in Anaesthesiology, 2009
- Capnographic Monitoring of Respiratory Activity Improves Safety of Sedation for Endoscopic Cholangiopancreatography and UltrasonographyGastroenterology, 2009
- Microstream Capnography Improves Patient Monitoring During Moderate Sedation: A Randomized, Controlled TrialPediatrics, 2006
- Performance of Nasal Prongs in Sleep StudiesChest, 2001
- Detection of Flow Limitation with a Nasal Cannula/ Pressure Transducer SystemAmerican Journal of Respiratory and Critical Care Medicine, 1998
- Evaluation of Nasal Prongs for Estimating Nasal FlowAmerican Journal of Respiratory and Critical Care Medicine, 1997
- Mechanisms of Hypoxemia during PanendoscopyJournal of Clinical Gastroenterology, 1989