Inflammatory Response with Osteolysis Related to a Bioabsorbable Anchor in the Finger: A Case Report
Authors:
Open Access
- 7 November 2009
- journal article
- research article
- Published by SAGE Publications in HAND
- Vol. 5 (3) , 307-312
Abstract
Soft tissue fixation of ligaments and tendons in the hand can be achieved by the use of metal or bioabsorbable suture anchors. Advantages of bioabsorbable suture anchors include lack of interference in magnetic resonance imaging, resorption of anchor, replacement by bone, and no need for hardware removal. However, complications of these bioabsorbable implants include inflammatory response to the material use. We present what we believe to be the first case in the hand of a poly(L-lactide-co-D,L-lacitide) suture anchor causing an inflammatory response leading to significant osteolysis 4 months postoperatively after repair of a ring finger flexor digitorum profundus avulsion. Exploration of the distal phalanx revealed an intact implant and repair, no signs of infection, and an extensive bone defect. Pathology showed chronically inflamed tissue. This case has led us to reconsider the use of bioabsorbable anchor sutures in the hand. Further research is necessary to better define the contraindications to bioabsorbable suture anchor use in the hand.Keywords
This publication has 33 references indexed in Scilit:
- Sterile Pretibial Abscess After Anterior Cruciate Reconstruction From Bioabsorbable Interference Screws: A Report of 2 CasesArthroscopy, 2006
- Bioabsorbable Implants in the Treatment of Hand Fractures: An UpdateClinical Orthopaedics and Related Research, 2006
- Comparison of Pullout Button Versus Suture Anchor for Zone I Flexor Tendon RepairThe Journal of Hand Surgery, 2006
- Cyclic Testing of Pullout Sutures and Micro-Mitek Suture Anchors in Flexor Digitorum Profundus Tendon Distal FixationThe Journal of Hand Surgery, 2005
- Extensive Osteolysis after Rotator Cuff Repair with a Bioabsorbable Suture Anchor: A Case ReportThe American Journal of Sports Medicine, 2005
- Use of Bioabsorbable Osteofixation Devices in the HandJournal of Hand Surgery (European Volume), 2004
- In vivo comparison of a metal versus a biodegradable suture anchor 1Arthroscopy, 2004
- Bioabsorbable Miniplating Versus Metallic Fixation for Metacarpal FracturesClinical Orthopaedics and Related Research, 2003
- Bioabsorbable fixation in orthopaedic surgery and traumatologyBiomaterials, 2000
- The mitek mini G2 suture anchor: Biomechanical analysis of use in the handThe Journal of Hand Surgery, 1995