Esophageal Magnetic Resonance Fluoroscopy
Authors:
- Hideaki KawamitsuHKHideaki Kawamitsu
- Takanori HigashinoTHTakanori Higashino
- Hong LeeHLHong Lee
- Masahiko FujiiMFMasahiko Fujii
- Hiroaki HoshiHHHiroaki Hoshi
- Kazuro SugimuraKSKazuro Sugimura
- 1 September 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 28 (5) , 697-703
Abstract
The purpose of this study was to try to delineate the esophageal passage under dynamic conditions and to determine optimum settings for esophageal magnetic resonance (MR) imaging. Ten healthy volunteers underwent MR fluoroscopy with two T1-weighted sequences: turbo field echo (TFE) and T1-weighted fast field echo (T1-FFE). These sequences were compared for signal-to-noise ratios (SNRs) and image quality. To determine the optimum slice thickness, an additional 10 healthy volunteers underwent MR fluoroscopy. Results obtained for slice thicknesses of 25, 35, 45, and 55 mm were compared for delineated length of the esophagus and image quality. The T1-FFE sequences provided higher SNRs and better image quality than the TFE sequences (T1-FFE: 89.4 ± 28.0, TFE: 52.4 ± 16.7; P < 0.001). Artifacts were less prominent and delineation of the esophageal wall was better on the T1-FFE images. The delineation of the esophageal wall was best with a 35-mm slice thickness, although delineated length was the longest with a 55-mm slice thickness. This study showed T1-FFE to be a more suitable sequence than TFE and that the 35-mm slice thickness was the optimum slice thickness for esophageal MR fluoroscopy.Keywords
This publication has 5 references indexed in Scilit:
- Evaluation of the anatomical and functional properties of deglutition with various kinetic high‐speed MRI sequencesJournal of Magnetic Resonance Imaging, 2001
- The clinical value of ferric ammonium citrate: A positive oral contrast agent for T1-weighted MR imaging of the upper abdomenJournal of Magnetic Resonance Imaging, 2000
- Patterns of lingual tissue deformation associated with bolus containment and propulsion during deglutition as determined by echo-planar MRIJournal of Magnetic Resonance Imaging, 1998
- Kinetic magnetic resonance imaging analysis of swallowing: a new approach to pharyngeal functionSurgical and Radiologic Anatomy, 1998
- Dynamic analysis of the pharynx during swallowing using Turbo-FLASH magnetic resonance imaging combined with an oral positive contrast agent—a preliminary studyBritish Journal of Radiology, 1995