Leveraging flow mechanics to determine critical process and scaling parameters in a continuous viral inactivation reactor
- 10 November 2019
- journal article
- research article
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 117 (3) , 637-645
Abstract
A continuous viral inactivation (CVI) chamber has been designed to operate with acceptable residence time distribution (RTD) characteristics. However, altering the CVI's geometry and operation to accommodate the scale was not obvious. In this work, we elucidate the influence of Dean vortices and leverage the transition into the weak turbulent regime to establish relationships between input variables and process outputs. This study was targeted to understand and quantify the impact of viscosity, Dean number, internal diameter, and path length on the RTD. When the Dean number exceeds 70, radial mixing generated by the Dean vortices began to consistently alter the axial dispersive effects experienced by the pulse injection. Increasing to a Dean number of >100, the axial dispersive effects were dominated by the Dean vortices which allowed the calculation of the minimum and maximum residence time to be generated. This work provides a method to calculate operational solutions for a tubular incubation reactor in terms of path length, internal diameter, flow rate, and target minimum and maximum residence time specifications that assures both viral residence times while also establishing criteria to maximize product quality during continuous operation.Keywords
This publication has 10 references indexed in Scilit:
- Continuous In‐Line Virus Inactivation for Next Generation BioprocessingBiotechnology Journal, 2018
- Design of a novel continuous flow reactor for low pH viral inactivationBiotechnology and Bioengineering, 2017
- Design, construction, and optimization of a novel, modular, and scalable incubation chamber for continuous viral inactivationBiotechnology Progress, 2017
- Adapting viral safety assurance strategies to continuous processing of biological productsBiotechnology and Bioengineering, 2016
- Continuous viral inactivation at low pH value in antibody manufacturingChemical Engineering and Processing - Process Intensification, 2016
- Characterization of operating parameters for XMuLV inactivation by low p H treatmentBiotechnology Progress, 2015
- Concentration Dependent Viscosity of Monoclonal Antibody Solutions: Explaining Experimental Behavior in Terms of Molecular PropertiesPharmaceutical Research, 2014
- Laminar-turbulent transition in Taylor-Dean flowJournal of Physics: Conference Series, 2005
- Bracketed generic inactivation of rodent retroviruses by low pH treatment for monoclonal antibodies and recombinant proteinsBiotechnology and Bioengineering, 2003
- Chemical Reaction EngineeringIndustrial & Engineering Chemistry Research, 1999