Ventriculostomy infections: the effect of monitoring duration and catheter exchange in 584 patients
Authors:
- Kathryn L. HollowayKHKathryn L. Holloway
- Tom BarnesTBTom Barnes
- Sung ChoiSCSung Choi
- Ross BullockRBRoss Bullock
- Lawrence F. MarshallLMLawrence F. Marshall
- Howard M. EisenbergHEHoward M. Eisenberg
- John A. JaneJJJohn A. Jane
- John D. WardJWJohn D. Ward
- Harold F. YoungHYHarold F. Young
- Anthony MarmarouAMAnthony Marmarou
- 1 September 1996
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 85 (3) , 419-424
Abstract
✓ The investigators undertook a retrospective analysis of ventriculostomy infections to evaluate their relationship to monitoring duration and prophylactic catheter exchange. In 1984, the results of an epidemiological study of ventriculostomy-related infection were published. One of the conclusions of the paper was that the incidence of ventriculostomy-related infections rose after 5 days of monitoring. This led to the recommendation that catheters be prophylactically changed at 5-day intervals if prolonged monitoring was required. A recent randomized prospective study on central venous catheters showed no reduction in infection with prophylactic catheter exchanges. This has led the authors to reexamine their experience with ventriculostomy infections. Data on 584 severely head injured patients with ventriculostomies were prospectively collected in two data banks, The Traumatic Coma Data Bank and The Medical College of Virginia Neurocore Data Bank. These data were retrospectively analyzed for factors associated with ventriculostomy related infections. It was found that there is a relationship of ventriculitis to monitoring duration but it is not simple or linear. There is a rising risk of infection over the first 10 days, but infection then becomes very unlikely despite a population that continues to be at risk. Patients in whom catheters were replaced prior to 5 days did not have a lower infection rate than those whose catheters were exchanged at more than 5-day intervals. Based on these data, it is recommended that ventriculostomy catheters for intracranial pressure monitoring be removed as quickly as possible, and in circumstances in which prolonged monitoring is required, there appears to be no benefit from catheter exchange.Keywords
This publication has 15 references indexed in Scilit:
- Duration of Intracranial Pressure Monitoring Does Not Predict Daily Risk of Infectious ComplicationsNeurosurgery, 1993
- Bacterial Ventriculitis and Duration of Ventriculostomy Catheter InsertionJournal of Neuroscience Nursing, 1993
- A Controlled Trial of Scheduled Replacement of Central Venous and Pulmonary-Artery CathetersNew England Journal of Medicine, 1992
- Complications of Intracranial Pressure Monitoring in Trauma PatientsNeurosurgery, 1989
- Comparison among Three Methods of Intracranial Pressure RecordingNeurosurgery, 1986
- Infectious complications and duration of intracranial pressure monitoringCritical Care Medicine, 1985
- Ventriculostomy-Related InfectionsNew England Journal of Medicine, 1984
- Intracranial pressure: to monitor or not to monitor?Journal of Neurosurgery, 1982
- Infections complicating the use of external ventriculostomyJournal of Neurosurgery, 1976
- Use of antibiotics with external ventriculostomiesJournal of Neurosurgery, 1972