Removal of Catalyst Particles from Oil Slurry by Hydrocyclone
Authors:
- 15 June 2009
- journal article
- research article
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 44 (9) , 2067-2077
Abstract
Small diameter (10 mm) hydrocyclone is used for catalyst particles separations in this work. An industrial sidetrack tester was set up in 1.8 Mt/a catalytic cracking unit. When Reynolds number is invariable, the experimental results show that the pressure drop between the inlet and the overflow is not changed by changes in the split ratio. The effects of Reynolds number and split ratio on separation efficiency were studied. The removed efficiency of catalyst particle is more than 55% with Reynolds number of 850 ∼ 950.Keywords
This publication has 4 references indexed in Scilit:
- Application of hydrocyclone for removal of yeasts from alcohol fermentations brothChemical Engineering Journal, 2008
- Nano-crystal glass?ceramics obtained from high alumina coal fly ashFuel, 2005
- Fuel oil desalting by hydrogel hollow fiber membraneJournal of Membrane Science, 2001
- Sub-micron particle dewatering using hydrocyclonesChemical Engineering Journal, 2000