Patients’ Radiation Dose During Videofluoroscopic Swallowing Studies According to Underlying Characteristics
Authors:
- 9 September 2012
- journal article
- research article
- Published by Springer Nature in Dysphagia
- Vol. 28 (2) , 153-158
Abstract
The videofluoroscopy swallowing study (VFSS) is regarded as the gold standard in diagnosing and assessing swallowing disorders. The goal of this study was to evaluate patients’ radiation dose during a VFSS and to determine the influence of patients’ underlying characteristics on radiation exposure risk. A total of 295 patients who underwent VFSS were included in this study. The fluoroscopy machine was equipped with a dose area product (DAP). The mean screening time was 4.82 ± 1.80 min and the mean DAP was 9.62 ± 5.01 Gy cm2. The mean effective dose was 1.23 ± 0.64 mSv. Screening time and DAP had a positive correlation (r = 0.76, P < 0.0001). The cerebrovascular accident (CVA) group showed higher screening time and DAP than the nasopharyngeal cancer (NPC) group with statistical significance. Patients’ BMI and DAP had a positive correlation (r = 0.28, P < 0.0001), and height, weight, and body surface area (BSA) also showed positive correlations with DAP. Radiation dose during VFSS is much lower than that of a routine chest CT, and it would take more than 40 VFSSs annually to exceed the annual radiation exposure dose limit according to the mean effective radiation exposure dose of this study. As it is difficult to exceed the annual dose limit, we assume that VFSS is relatively safe in terms of its radiation exposure risk.Keywords
This publication has 13 references indexed in Scilit:
- Radiation Exposure from CT Examinations in JapanBMC Medical Imaging, 2010
- Speech and language therapy for aphasia following stroke2010
- Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of CancerArchives of internal medicine (1960), 2009
- Patient Dose During Videofluoroscopy Swallowing Studies in a Hong Kong Public HospitalDysphagia, 2009
- Obesity Is a Major Determinant of Radiation Dose in Patients Undergoing Pulmonary Vein Isolation for Atrial FibrillationJACC, 2007
- Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac proceduresBritish Journal of Radiology, 2003
- Fluoroscopy: Recording of Fluoroscopic Images and Automatic Exposure ControlRadioGraphics, 2001
- Clinical Utility of the Modified Barium SwallowDysphagia, 2000
- Radiation Doses to Patients during Pharyngeal VideofluoroscopyDysphagia, 1998
- Role of the modified barium swallow in management of patients with dysphagiaOtolaryngology–Head and Neck Surgery, 1997