Timepix Radiation Detector for Autonomous Radiation Localization and Mapping by Micro Unmanned Vehicles
Authors:
- 1 November 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1129-1136
Abstract
A system for measuring radiation intensity and for radiation mapping by a micro unmanned robot using the Timepix detector is presented in this paper. Timepix detectors are extremely small, but powerful 14 × 14 mm, 256 × 256 px CMOS hybrid pixel detectors, capable of measuring ionizing alpha, beta, gamma radiation, and heaving ions. The detectors, developed at CERN, produce an image free of any digital noise thanks to per-pixel calibration and signal digitization. Traces of individual ionizing particles passing through the sensors can be resolved in the detector images. Particle type and energy estimates can be extracted automatically using machine learning algorithms. This opens unique possibilities in the task of flexible radiation detection by very small unmanned robotic platforms. The detectors are well suited for the use of mobile robots thanks to their small size, lightweight, and minimal power consumption. This sensor is especially appealing for micro aerial vehicles due to their high maneuverability, which can increase the range and resolution of such novel sensory system. We present a ROS-based readout software and real-time image processing pipeline and review options for 3-D localization of radiation sources using pixel detectors. The provided software supports off-the-shelf FITPix, USB Lite readout electronics with Timepix detectors.Keywords
This publication has 30 references indexed in Scilit:
- Lightweight aerial vehicles for monitoring, assessment and mapping of radiation anomaliesJournal of Environmental Radioactivity, 2014
- Timepix3: a 65K channel hybrid pixel readout chip with simultaneous ToA/ToT and sparse readoutJournal of Instrumentation, 2014
- Low-cost Multi-UAV Technologies for Contour Mapping of Nuclear Radiation FieldJournal of Intelligent & Robotic Systems, 2012
- Radiation Mapping in Post-Disaster Environments Using an Autonomous HelicopterRemote Sensing, 2012
- 3D sensitive voxel detector of ionizing radiation based on Timepix deviceJournal of Instrumentation, 2011
- Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectorsJournal of Instrumentation, 2011
- FITPix — fast interface for Timepix pixel detectorsJournal of Instrumentation, 2011
- Performance of an air sampler and a gamma-ray detector in a small unmanned aerial vehicleJournal of Radioanalytical and Nuclear Chemistry, 2009
- Radiation surveillance using an unmanned aerial vehicleApplied Radiation and Isotopes, 2009
- Design of a radiation surveillance unit for an unmanned aerial vehicleJournal of Environmental Radioactivity, 2005