The efficacy of tumor characterization and tumor detectability of linked color imaging and blue laser imaging with an LED endoscope compared to a LASER endoscope
Authors:
- 22 February 2020
- journal article
- research article
- Published by Springer Nature in International Journal of Colorectal Disease
- Vol. 35 (5) , 815-825
Abstract
Objectives An endoscope with a light-emitting diode (LED) light source which has a 2-mm close-distance observation function without magnification, has been marketed, enabling linked color imaging (LCI) and blue laser imaging (BLI) for tumor detection and characterization. We analyzed the efficacy of a LED endoscope compared to a LASER endoscope. Methods We retrospectively reviewed 272 lesions observed using the LED endoscopic system (Fujifilm Co., Tokyo, Japan) from May 2018 to September 2019. The Japanese NBI Classification was used for tumor characterization. We analyzed the diagnostic accuracy and confidence level. Sixty-one lesions observed with both the LED and magnified LASER endoscopes were also analyzed to compare the diagnostic accuracy. Regarding the tumor detectability, we calculated color difference values (CDVs) and brightness values (BVs) of white-light imaging, BLI, and LCI modes between the two endoscopes for each tumor. Results The mean polyp size was 9.2 ± 11.3 mm. Histology showed 71 sessile serrated lesions, 193 adenoma and high-grade dysplasias, and 8 T1 cancers. The diagnostic accuracy of tumors ≥ 10 and < 10 mm was 72.0% and 92.9% (p < 0.001), respectively and the high confidence rate was 93.8%. The diagnostic accuracy of LED (77.0%) was a little higher than that of LASER without magnification (65.6%, p = 0.16) but was not inferior to that of LASER with magnification (82.0%, p = 0.50). The respective CDVs of LED and LASER endoscopes were 20.6 ± 11.2 and 21.6 ± 11.2 for LCI (p = 0.30), and the respective BVs were 210.0 ± 24.2 and 175.9 ± 21.1 (p < 0.001). Conclusions A LED endoscope with close-distance observation improved tumor detection and characterization due to high brightness.Keywords
This publication has 28 references indexed in Scilit:
- Improvement in the visibility of colorectal polyps by using blue laser imaging (with video)Gastrointestinal Endoscopy, 2015
- Diagnostic features of sessile serrated adenoma/polyps on magnifying narrow band imaging: A prospective study of diagnostic accuracyJournal of Gastroenterology and Hepatology, 2014
- Present and future status of flexible spectral imaging color enhancement and blue laser imaging technologyDigestive Endoscopy, 2013
- Long-Term Colorectal-Cancer Incidence and Mortality after Lower EndoscopyNew England Journal of Medicine, 2013
- Ability of a novel blue laser imaging system for the diagnosis of colorectal polypsDigestive Endoscopy, 2013
- The ability of a novel blue laser imaging system for the diagnosis of invasion depth of colorectal neoplasmsJournal of Gastroenterology, 2013
- Colonoscopic Polypectomy and Long-Term Prevention of Colorectal-Cancer DeathsNew England Journal of Medicine, 2012
- Narrow-band imaging magnification predicts the histology and invasion depth of colorectal tumorsGastrointestinal Endoscopy, 2009
- The Paris endoscopic classification of superficial neoplastic lesions: esophagus, stomach, and colonGastrointestinal Endoscopy, 2003
- COHERENT (VISIBLE) LIGHT EMISSION FROM Ga(As1−xPx) JUNCTIONSApplied Physics Letters, 1962