Traditional coating techniques in scanning electron microscopy compared to uncoated charge compensator technology: Looking at human blood fibrin networks with the ZEISS ULTRA Plus FEG‐SEM
- 24 March 2011
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 74 (4) , 343-346
Abstract
Scanning electron microscopy (SEM) studies surface morphology. Biological material needs to be coated to render the material conductive, and gold coating is traditionally used, although other coating material like carbon and ruthenium vapors may also be used. With modern SEM technology (e.g., ZEISS ULTRA Plus FEG‐SEM), we are able to work at very low kilovolts and also view fine surface structure in much better detail than with previous older technology. Some machines also allow for the study of uncoated material, although this is usually not done with biological material. This study focuses on surface clarity by comparing gold, ruthenium vapor, and carbon coating techniques for biological material. Human fibrin networks are used as example. Uncoated specimens are also viewed with a ZEISS ULTRA Plus FEG‐SEM because of its unique nitrogen charge compensator, and here, the first micrographs for uncoated human fibrin networks versus carbon, gold, and ruthenium coating are shown. We conclude that gold coating for biological material is not preferable with the latest SEM machines, as this method forms gold islands on top of the biological material and therefore produces a false surface morphology. Microsc. Res. Tech., 2011.Keywords
This publication has 8 references indexed in Scilit:
- Architecture of the thrombi removed from coronary artery bypass grafts in a patient with acute myocardial infarctionJournal of Thrombosis and Thrombolysis, 2010
- Influence of acceleration voltage on scanning electron microscopy of human blood plateletsMicroscopy Research and Technique, 2010
- Architecture of intraluminal thrombus removed from abdominal aortic aneurysmJournal of Thrombosis and Thrombolysis, 2009
- Ultrastructural Changes in Platelet Aggregates of HIV Patients: A Scanning Electron Microscopy StudyUltrastructural Pathology, 2008
- Ultrastructural comparison of the morphology of three different platelet and fibrin fiber preparationsThe Anatomical Record, 2007
- SEM examination of human erythrocytes in uncoated bloodstains on stone: use of conventional as environmental‐like SEM in a soft biological tissue (and hard inorganic material)Journal of Microscopy, 2005
- Recent advances in electron imaging, image interpretation and applications: environmental scanning electron microscopyPhilosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2003
- An investigation of the use of chromium, platinum and gold coating for scanning electron microscopy of casts of lymphoid tissuesMicron, 1995