Experimental Investigations and Operational Performance Analysis on Compressed Natural Gas Home Refueling System (CNG-HRS)
Open Access
Abstract
Compressed natural gas can be globally used as fuel for combustion engines to reduce CO2 emission without negative impact on economy. Lack of refueling infrastructure is one of reason why NGVs shares only ~1.6% in total vehicle fleet worldwide. Operational tests of CNG home fast refueling station were performed to investigate: (i) natural gas demand, m3/h; (ii) energy consumption, kW/h; and (iii) total cost of one refueling. Two scenarios for operational tests were developed to monitor and collect data. Safety tests for leakage, fill pressure change, interrupted power and gas supply, temperature, and unexpected failures were performed. This article present results of operational and safety tests of compressed natural gas home, fast refueling station (CNG-HRS) based on one stage hydraulic compressor. The average duration of HRS full operating cycle was 7 h and 32 min (buffering and refueling mode). The average electric energy and natural gas consumption for one full cycle was 5.52 kWh and 7.5 m3, respectively. Safety tests results for leakage, fill pressure change, interrupted power and gas supply, temperature and unexpected failures demonstrated valid operation of HRS which positively affects the general safety level. To compare HRS with large scale CNG refueling infrastructure the costs of 1 Nm3 CNG was estimated for both solutions. Results shows that home refueling appliance might be become a solution for filling the gap in CNG refueling infrastructure.Keywords
Funding Information
- CC Poland Plus KIC InnoEnergy (7.7.190.70130)
This publication has 14 references indexed in Scilit:
- Natural gas as a bridge to hydrogen transportation fuel: Insights from the literatureEnergy Policy, 2018
- Decentralized refueling of compressed natural gas (CNG) fleet vehicles in Southern CaliforniaEnergy Policy, 2017
- Demand Assessment and Design Aspect of City Gas Distribution Network2017
- Selecting optimal volume ratio of reservoir tanks in CNG refueling station with multi-line storage systemInternational Journal of Hydrogen Energy, 2016
- Technological and safety aspects of CNG home fast refueling unitsAGH Drilling, Oil, Gas, 2016
- Technical overview of compressed natural gas (CNG) as a transportation fuelRenewable and Sustainable Energy Reviews, 2015
- Effects of Natural Gas Compositions on CNG Fast Filling Process for Buffer Storage SystemOil & Gas Science and Technology – Revue d’IFP Energies nouvelles, 2013
- Opportunities and challenges for a sustainable energy futureNature, 2012
- Natural gas vehicles: An option for EuropeEnergy Policy, 2010
- An Overview of Automotive Home and Neighborhood RefuelingWorld Electric Vehicle Journal, 2009