Balloon Angioplasty for Disruption of Tunneled Dialysis Catheter Fibrin Sheath
- 29 September 2011
- journal article
- research article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 13 (1) , 111-114
Abstract
Purpose: Management of failing tunneled hemodialysis catheters, sometimes the only vascular access for hemodialysis, presents a difficult problem. In spite of various techniques having been developed, no consensus has been reached about the preferred technique, associated with the longest catheter patency. Methods: We report disruption of the fibrin sheath covering dysfunctional tunneled hemodialysis catheter by means of angioplasty, followed by over guidewire catheter exchange. Results: Following the procedure, the catheter placed in the recovered lumen of the vessel presented correct function. Conclusions: The described procedure allowed maintenance of vascular access in our patient. Additionally, dilatation of the concomitant central vein stenosis opens an option for another attempt for arteriovenous fistula creation.Keywords
This publication has 14 references indexed in Scilit:
- Catheter Patency and Function after Catheter Sheath DisruptionClinical Journal of the American Society of Nephrology, 2007
- Central Vein Stenosis: A Nephrologist's PerspectiveSeminars in Dialysis, 2007
- 2005 Annual Report: ESRD Clinical Performance Measures ProjectAmerican Journal of Kidney Diseases, 2006
- Impact of Dialysis Dose and Membrane on Infection-Related Hospitalization and DeathJournal of the American Society of Nephrology, 2003
- Utility of Percutaneous Intervention in the Management of Tunneled Hemodialysis CathetersCardioVascular and Interventional Radiology, 2003
- Epidemiology of hemodialysis vascular access infections from longitudinal infection surveillance data: Predicting the impact of NKF-DOQI clinical practice guidelines for vascular accessAmerican Journal of Kidney Diseases, 2002
- Fibrin Sheath Stripping versus Catheter Exchange for the Treatment of Failed Tunneled Hemodialysis Catheters: Randomized Clinical TrialJournal of Vascular and Interventional Radiology, 2000
- Hemodialysis Catheter-associated Fibrin Sheaths: Treatment with a Low-Dose rt-PA InfusionJournal of Vascular and Interventional Radiology, 2000
- Percutaneous Fibrin Sheath Stripping versus Transcatheter Urokinase Infusion for Malfunctioning Wellpositioned Tunneled Central Venous Dialysis Catheters: A Prospective, Randomized TrialJournal of Vascular and Interventional Radiology, 2000
- Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters.American Journal of Roentgenology, 1999