Effect of Reamer Design on Posteriorization of the Tibial Tunnel During Endoscopic Transtibial Anterior Cruciate Ligament Reconstruction
Authors:
- 12 April 2013
- journal article
- research article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 41 (6) , 1282-1289
Abstract
It is known that small alterations in tunnel positioning during anterior cruciate ligament (ACL) reconstruction significantly affect ACL length and tensioning patterns as well as alter force vectors and joint kinematics. To compare the amount of inadvertent posteriorization of the ACL tibial tunnel anatomy during transtibial ACL femoral reaming in the “over-the-top” position with a full femoral reamer versus a half femoral reamer, in comparison to the native tibial ACL footprint. It is hypothesized that the half reamer will result in less distortion of tibial tunnel anatomy and improved anatomic footprint coverage. It is also hypothesized that the true center of the tibial ACL footprint lies more anterior than previously described. Controlled laboratory study. Eight cadaveric knee specimens were securely fixed to a stationary table at 90° of flexion and neutral rotation. After removal of the anterior capsule and patella, native joint anatomy was precisely recorded with a digitizer accurate to 0.05 mm. Tibial and femoral tunnels were then drilled in the manner of transtibial ACL reconstructions using the optimal tibial starting point of 15.9 mm below the medial plateau and 9.8 mm posteromedial to the medial margin of the tibial tubercle. After the 11-mm tibial tunnel was drilled, femoral tunnels were first drilled with a 10-mm half-fluted reamer, followed by a 10-mm full reamer. Each tibial tunnel’s location and geometry relative to the native ligamentous insertion sites and joint anatomy were digitized. Digitized measurements of ACL insertional anatomy demonstrated that the center of the native ACL tibial footprint was 2.0 ± 0.49 mm (range, 1.1-2.7 mm) anterior to the posterior aspect of the lateral meniscus’ anterior horn. Use of the 10-mm full femoral reamer resulted in a tibial-articular aperture that had a posterior edge 4.35 mm more posterior (P = .049) and extra-anatomic (P = .006) than the footprint of the 10-mm half femoral reamer. Half-fluted reamers may be more advantageous for femoral tunnel reaming with a more oblique transtibial approach, as they result in less posterior tibial tunnel expansion than full reamers, possibly leading to improved graft function. Based on the digitized anatomy, the center of the tibial attachment site is anterior to the posterior aspect of the lateral mensicus’s anterior horn, which has been traditionally described as the anatomic center. Use of half-fluted reamers for transtibial femoral tunnel reaming could lead to more anatomic tunnel placement and possibly improved graft mechanics after transtibial single-bundle ACL reconstruction.Keywords
This publication has 21 references indexed in Scilit:
- Biomechanical Evaluation of Knee Joint Laxities and Graft Forces After Anterior Cruciate Ligament Reconstruction by Anteromedial Portal, Outside-In, and Transtibial TechniquesThe American Journal of Sports Medicine, 2011
- The effect of femoral tunnel placement on ACL graft orientation and length during in vivo knee flexionJournal of Biomechanics, 2011
- The effects of femoral graft placement on in vivo knee kinematics after anterior cruciate ligament reconstructionJournal of Biomechanics, 2011
- Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2011
- Arthroscopically Pertinent Landmarks for Tunnel Positioning in Single-Bundle and Double-Bundle Anterior Cruciate Ligament ReconstructionsThe American Journal of Sports Medicine, 2010
- Effect of Tibial Tunnel Position on Stability of the Knee After Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2010
- Single-Bundle Anterior Cruciate Ligament ReconstructionThe American Journal of Sports Medicine, 2009
- Using Navigation to Measure Rotation Kinematics during ACL ReconstructionClinical Orthopaedics and Related Research, 2007
- Tibial Rotation is Not Restored after ACL Reconstruction with a Hamstring GraftClinical Orthopaedics and Related Research, 2007
- Sensitivity of Insertion Locations on Length Patterns of Anterior Cruciate Ligament FibersJournal of Biomechanical Engineering, 1986