Upgrading the ISIS muon beamlines
Authors:
Open Access
- 1 April 2026
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3222 (1) , 012017
Abstract
The ISIS muon beamlines have been operating for nearly 40 years and we have recently undertaken a phased programme of refurbishment. We give an overview of the work and performance improvements obtained. The first muon beamline at ISIS started operation in 1987, and in 1993 the EMU and DEVA (now HIFI) ports were added. In 2014 we replaced the front end quadrupole doublet with a larger aperture triplet and in 2016 we replaced the remaining quadrupoles in the original beamline, taking the opportunity to improve the beam optics, and refurbished the other components. The RIKEN beamlines were constructed in 1994 with 3 ports, and Port 4 added in 2002. The refurbishment in 2021-2 involved repairing the magnets, replacing insulators on separators, adding new water services and modifying the shielding for ease of future maintenance. A replacement for the 30 year old superconducting solenoid is being manufactured. Both beamlines are now controlled by the ISIS standard “IBEX” control system based on EPICS, which allows automatic initialisation of the beam parameters, logging and alarms, and beam tuning while optimising the data on the instruments. This is particularly useful for configuring the beam momentum and polarity on the RIKEN instruments.Keywords
This publication has 7 references indexed in Scilit:
- Activation of the ISIS muon beamline and corresponding gamma dose ratesJournal of Physics: Conference Series, 2018
- Mantid—Data analysis and visualization package for neutron scattering and SR experimentsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2014
- Design and commissioning of a high magnetic field muon spin relaxation spectrometer at the ISIS pulsed neutron and muon sourceReview of Scientific Instruments, 2011
- The RIKEN-RAL pulsed Muon FacilityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2001
- Fast E-field switching of a pulsed surface muon beam: The commissioning of the European muon facility at ISISNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994
- Uppset: A pulsed electrostatic kicker to improve the μSR frequency response in the ISIS pulsed muon beamNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1990
- Commissioning of the Rutherford Appleton Laboratory pulsed muon facilityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1988