Comparison of intraocular pressure measurements between the Tono‐Pen XL®and Perkins®applanation tonometers in dogs and cats
- 12 July 2011
- journal article
- research article
- Published by Wiley in Veterinary Ophthalmology
- Vol. 15 (s1) , 14-20
Abstract
Objective To compare the accuracy between two applanation tonometers, Tono‐Pen XL®and Perkins®, in ophthalmoscopically normal dogs and cats.Animals Both eyes of 25 conscious and healthy dogs and cats were evaluated. Both eyes of five dogs and cats immediately after sacrifice were used as controls for the postmortem study.Procedure In conscious animals, the tonometry was performed with topical anesthesia using 0.5% proxymetacaine eye drops for both tonometers and 1% fluorescein eye drops for the Perkins tonometer. Readings of intraocular pressure (IOP) in the postmortem study were taken using manometry and tonometry by Tono‐Pen XL®and Perkins®.Results The correlation coefficient (r2) in dogs between manometry and applanation tonometers Tono‐Pen XL®and Perkins®were, respectively, 0.896 and 0.981 and in cats were 0.905 and 0.988. The mean IOP values in conscious dogs with Tono‐Pen XL®and Perkins®were, respectively, 17.5 ± 3.7 mmHg (10.0–25.0 mmHg) and 15.3 ± 2.1 mmHg (12.0–19.8 mmHg) and in conscious cats were 16.8 ± 3.6 mmHg (10.5–24.5 mmHg) and 15.5 ± 1.3 mmHg (13.0–18.5 mmHg).Conclusion There was a strong correlation between the IOP values obtained by direct ocular manometry and the Tono‐Pen XL®and Perkins®tonometers in dogs and cats. There was no statistically significant difference between the mean IOP obtained with both tonometers in conscious animals, there was, however, a difference between the minimum and mainly in the maximum values that were on average 5–6 mmHg higher with Tono‐Pen XL®than those measured with Perkins®, which justifies a table of normal values differentiated for each tonometer.Keywords
This publication has 14 references indexed in Scilit:
- Evaluation of the Perkins®handheld applanation tonometer in the measurement of intraocular pressure in dogs and catsVeterinary Ophthalmology, 2009
- The Glaucomas2008
- Comparison of simultaneous readings of intraocular pressure in rabbits using Perkins handheld, Tono-Pen XL, and TonoVet tonometersGraefe's Archive for Clinical and Experimental Ophthalmology, 2006
- Comparison of the rebound tonometer (ICare®) to the applanation tonometer (Tonopen XL®) in normotensive dogsVeterinary Ophthalmology, 2006
- Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horsesJournal of the American Veterinary Medical Association, 2005
- Accuracy of Intraocular Pressure Measurements in New Zealand White RabbitsInvestigative Ophthalmology & Visual Science, 2005
- Steroid-Induced Ocular Hypertension in Normal CattleArchives of Ophthalmology (1950), 2004
- Tono‐Pen XL®calibration curves for cats, cows and sheepVeterinary Ophthalmology, 2004
- New TonoPen XL: Comparison with the Goldmann tonometerEye, 2001
- Calibration of the Alcon applanation pneumatonograph and Perkins tonometer for use in rabbits and catsCurrent Eye Research, 1984