Detailed simulation of cancer exome sequencing data reveals differences and common limitations of variant callers
Open Access
- 3 January 2017
- journal article
- research article
- Published by Springer Nature in BMC Bioinformatics
- Vol. 18 (1) , 1-15
Abstract
Next-generation sequencing of matched tumor and normal biopsy pairs has become a technology of paramount importance for precision cancer treatment. Sequencing costs have dropped tremendously, allowing the sequencing of the whole exome of tumors for just a fraction of the total treatment costs. However, clinicians and scientists cannot take full advantage of the generated data because the accuracy of analysis pipelines is limited. This particularly concerns the reliable identification of subclonal mutations in a cancer tissue sample with very low frequencies, which may be clinically relevant. Using simulations based on kidney tumor data, we compared the performance of nine state-of-the-art variant callers, namely deepSNV, GATK HaplotypeCaller, GATK UnifiedGenotyper, JointSNVMix2, MuTect, SAMtools, SiNVICT, SomaticSniper, and VarScan2. The comparison was done as a function of variant allele frequencies and coverage. Our analysis revealed that deepSNV and JointSNVMix2 perform very well, especially in the low-frequency range. We attributed false positive and false negative calls of the nine tools to specific error sources and assigned them to processing steps of the pipeline. All of these errors can be expected to occur in real data sets. We found that modifying certain steps of the pipeline or parameters of the tools can lead to substantial improvements in performance. Furthermore, a novel integration strategy that combines the ranks of the variants yielded the best performance. More precisely, the rank-combination of deepSNV, JointSNVMix2, MuTect, SiNVICT and VarScan2 reached a sensitivity of 78% when fixing the precision at 90%, and outperformed all individual tools, where the maximum sensitivity was 71% with the same precision. The choice of well-performing tools for alignment and variant calling is crucial for the correct interpretation of exome sequencing data obtained from mixed samples, and common pipelines are suboptimal. We were able to relate observed substantial differences in performance to the underlying statistical models of the tools, and to pinpoint the error sources of false positive and false negative calls. These findings might inspire new software developments that improve exome sequencing pipelines and further the field of precision cancer treatment.Keywords
Funding Information
- SystemsX.ch IPhD Grant (SXPHI0_142005)
- SystemsX.ch RTD Grant (2013/150)
- ERC Synergy Grant (609883)
- ERC Synergy Grant (609883)
- European Commission's H2020 Programme SOUND (633974)
This publication has 45 references indexed in Scilit:
- Comparing somatic mutation-callers: beyond Venn diagramsBMC Bioinformatics, 2013
- Intra-tumour heterogeneity: a looking glass for cancer?Nature Reviews Cancer, 2012
- Fast gapped-read alignment with Bowtie 2Nature Methods, 2012
- JointSNVMix: a probabilistic model for accurate detection of somatic mutations in normal/tumour paired next-generation sequencing dataBioinformatics, 2012
- Control-FREEC: a tool for assessing copy number and allelic content using next-generation sequencing dataBioinformatics, 2011
- SomaticSniper: identification of somatic point mutations in whole genome sequencing dataBioinformatics, 2011
- A framework for variation discovery and genotyping using next-generation DNA sequencing dataNature Genetics, 2011
- BEDTools: a flexible suite of utilities for comparing genomic featuresBioinformatics, 2010
- Targeted capture and massively parallel sequencing of 12 human exomesNature, 2009
- Choosing an optimal method to combineP‐valuesStatistics in Medicine, 2009