Diminishing Endograft Apposition during Follow-Up Is an Important Indicator of Late Type 1a Endoleak after Endovascular Aneurysm Repair
Authors:
- Roy ZuidemaRZRoy Zuidema
- Anna C. M. GeraedtsAGAnna C. M. Geraedts
- Willemina A. van VeldhuizenWVWillemina A. van Veldhuizen
- Sana MulaySMSana Mulay
- Jean-Paul P. M. de VriesJean-Paul P. M. de Vries
- Richte C. L. SchuurmannRSRichte C. L. Schuurmann
- Ron BalmRBRon Balm
- the ODYSSEUS-T1EL Study GroupTGthe ODYSSEUS-T1EL Study Group
Open Access
- 10 June 2023
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (12) , 3969
Abstract
Late type 1a endoleaks (T1aELs) after endovascular aneurysm repair (EVAR) are hazardous complications which should be avoided. This study investigated the evolution of the shortest apposition length (SAL) post-EVAR and hypothesised that a declining apposition during follow-up may be an indicator of T1aEL development. Patients with a late T1aEL were selected from a consecutive multicentre database. For each T1aEL patient, the preoperative computed tomography angiography (CTA), first postoperative CTA, and pre-endoleak CTA were analysed. T1aEL patients were matched 1:1 to uncomplicated controls, based on endograft type and follow-up duration. Anatomical characteristics and endograft dimensions, including the post-EVAR SAL, were measured. Included were 28 patients with a late T1aEL and 28 matched controls. The SAL decreased from 11.2 mm (5.6–20.6 mm) to 3.9 mm (0.0–11.4 mm) in the T1aEL group (p = 0.006), whereas an increase in SAL was seen in the control group from 21.3 mm (14.1–25.8 mm) to 25.4 mm (19.0–36.2 mm; p = 0.015). On the pre-endoleak CTA, 18 patients (64%) in the T1aEL group had a SAL < 10 mm, and one (4%) patient in the control group had a SAL < 10 mm on the matched CTAs. Moreover, three mechanisms of decreasing sealing zone were identified, which might be used to determine optimal imaging or reintervention strategies. Diminishing SAL < 10 mm is an indicator for T1aEL during follow-up, it is imperative to include apposition analysis during follow-up.Keywords
This publication has 29 references indexed in Scilit:
- One Year Outcome Using Newer Generation Endografts: A National Multicenter Study on Real Word PracticeAnnals of Vascular Surgery, 2016
- An Experimental Evaluation of Device/Arterial Wall Compliance Mismatch for Four Stent-Graft Devices and a Multi-layer Flow Modulator Device for the Treatment of Abdominal Aortic AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2016
- Late Rupture of Abdominal Aortic Aneurysm After Previous Endovascular RepairJournal of Endovascular Therapy, 2015
- The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) Statement: Guidelines for reporting observational studiesInternational Journal of Surgery, 2014
- Early and delayed rupture after endovascular abdominal aortic aneurysm repair in a 10-year multicenter registryJournal of Vascular Surgery, 2014
- Results of the ANCHOR prospective, multicenter registry of EndoAnchors for type Ia endoleaks and endograft migration in patients with challenging anatomyJournal of Vascular Surgery, 2014
- Adequate seal and no endoleak on the first postoperative computed tomography angiography as criteria for no additional imaging up to 5 years after endovascular aneurysm repairJournal of Vascular Surgery, 2013
- Duplex Ultrasound and Contrast-Enhanced Ultrasound Versus Computed Tomography for the Detection of Endoleak after EVAR: Systematic Review and Bivariate Meta-AnalysisEuropean Journal of Vascular and Endovascular Surgery, 2010
- Freedom From Endoleak After Endovascular Aneurysm Repair Does Not Equal Treatment SuccessEuropean Journal of Vascular and Endovascular Surgery, 2000
- Anatomical Risk Factors for Proximal Perigraft Endoleak and Graft Migration Following Endovascular Repair of Abdominal Aortic AneurysmsEuropean Journal of Vascular and Endovascular Surgery, 2000