A wear resistant material for total joint replacement—tissue biocompatibility of an ultra‐high molecular weight (UHMW) polyethylene—graphite composite
Authors:
- 1 September 1974
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 8 (5) , 231-250
Abstract
A new prosthetic material, ultra‐high molecular weight (UHMW) polyethylene graphite, was developed for use in total joint replacement and found to exhibit 1/7–1/30 lower wear rate than UHMW polyethylene bearing against Vitallium alloy.A preliminary study was undertaken to test the biocompatibility of the new material. Specimens of 316L stainless steel, high‐purity graphite, UHMW polyethylene, and the composite material were implanted in rabbits and cynomologous monkeys. The materials were evaluated in both solid and particulate forms after implantation in bone, joint cavities, and paravertebral muscles. The tissue reactions to the materials were noted at time intervals from 6 weeks to 1 year.All materials showed good tissue acceptance in solid form. The UHMW polyethylene and the composite material were noted to be more reactive than either the high‐purity graphite alone or the stainless steel when in particulate form.The eventual use of the polyethylene graphite composite in total hip arthroplasties is suggested by virtue of its identical biocompatibility with UHMW polyethylene. In addition, its superior wear resistance, and hence low volume of wear debris particles presented to the surrounding tissues would offer an advantage in terms of longevity of the implant both mechanically and biologically.Keywords
This publication has 9 references indexed in Scilit:
- Elemental carbon as a biomaterialJournal of Biomedical Materials Research, 1971
- Skeletal extension of limb prosthetic attachments–problems in tissue reactionJournal of Biomedical Materials Research, 1971
- Quartz and graphite filament reinforced polymer composites for orthopedic surgical applicationJournal of Biomedical Materials Research, 1971
- Investigation of canine tissue reaction to TFE-fluorocarbon resin, to high-density polyethylene, and to vitalliumJournal of Surgical Research, 1970
- Tissue reaction in rabbit muscle exposed to metallic implantsJournal of Biomedical Materials Research, 1967
- Assay of Foreign-Body ReactionJournal of Bone and Joint Surgery, 1959
- THE UNSUITABILITY OF POLYTHENE FOR MOVABLE WEIGHT-BEARING PROSTHESESThe Journal of Bone and Joint Surgery. British volume, 1951
- Diseases of the Lung Resulting from Occupational Dusts other than SilicaThorax, 1947
- Bilateral Pulmonary Abscess Secondary to PneumonokoniosisDiseases of the Chest, 1940