The design and application of sequential extractions for mercury, Part 1. Optimization of HNO 3 extraction for all non-sulphide forms of Hg
Authors:
- 1 May 2005
- journal article
- Published by Geological Society of London in Geochemistry: Exploration, Environment, Analysis
- Vol. 5 (2) , 107-113
Abstract
The final step in a sequential extraction procedure for Hg in geological samples usually involves a strong acid attack such as aqua regia. It is assumed that the Hg component measured in this step represents HgS (cinnabar), the common and highly insoluble form of Hg in nature. This paper describes the optimization of an HNO 3 -based dissolution of all non-sulphide forms of Hg while minimizing the solubilization of HgS. Previous work indicated that 12M (75% v/v) HNO 3 would fulfil that objective but its application in this work to samples containing very fine-grained HgS showed that this concentration was too strong as it partially dissolved HgS. Thus, HgS control samples were used to study the effect of HNO 3 concentration, duration of extraction and sample-to-volume ratio on the chemical breakdown of HgS. The recommended procedure to separate HgS from other forms of Hg is a two-hour extraction of 1 g of sample in 20 ml of 40% HNO 3 with constant agitation followed by a 10-ml rinse with 40% HNO 3 . This then ensures that all the cinnabar, fine- and coarse-grained, reports to the subsequent aqua regia step.Keywords
This publication has 27 references indexed in Scilit:
- The design and application of sequential extractions for mercury, Part 2. Resorption of mercury onto the sample during leachingGeochemistry: Exploration, Environment, Analysis, 2005
- Evaluation of sequential and selective extraction methods for determination of mercury speciation and mobility in mine wasteApplied Geochemistry, 2003
- Selective extractions to assess the biogeochemically relevant fractionation of inorganic mercury in sediments and soilsAnalytica Chimica Acta, 2003
- Inhibition of Precipitation and Aggregation of Metacinnabar (Mercuric Sulfide) by Dissolved Organic Matter Isolated from the Florida EvergladesEnvironmental Science & Technology, 1999
- Mercury contamination in sandy soils surrounding an industrial emission source (Estarreja, Portugal)Geoderma, 1998
- Analysis of Geological Materials for Bismuth, Antimony, Selenium and Tellurium by Continuous Flow Hydride Generation Inductively Coupled Plasma Mass SpectrometryJournal of Analytical Atomic Spectrometry, 1997
- Evaluation of a Direct Solid Sampling Atomic Absorption Spectrometer for the Trace Determination of Mercury in Geological SamplesThe Analyst, 1997
- PROVISIONAL ELEMENTAL VALUES FOR FOUR NEW GEOCHEMICAL SOIL AND TILL REFERENCE MATERIALS, TILL‐1, TILL‐2, TILL‐3 AND TILL‐4Geostandards Newsletter, 1996
- Provisional Elemental Values for Eight New Geochemical Lake Sediment and Stream Sediment Reference Materials LKSD‐1, LKSD‐2, LKSD‐3, LKSD‐4, STSD‐1, STSD‐2, STSD‐3 and STSD‐4*Geostandards Newsletter, 1990
- Atomic-absorption determination of mercury in geological materials by flame and carbon-rod atomisation after solvent extraction and using co-extracted silver as a matrix modifierThe Analyst, 1983