Fractional Flow Reserve Compared With Intravascular Ultrasound Guidance for Optimizing Stent Deployment
Authors:
- William F. FearonWFWilliam F. Fearon
- Jorge LunaJLJorge Luna
- Habib SamadyHSHabib Samady
- Eric R. PowersEPEric R. Powers
- Ted FeldmanTFTed Feldman
- Nabil DibNDNabil Dib
- E. Murat TuzcuETE. Murat Tuzcu
- Michael W. ClemanMCMichael W. Cleman
- Tony M. ChouTCTony M. Chou
- David J. CohenDCDavid J. Cohen
- Michael RagostaMRMichael Ragosta
- Atsushi TakagiATAtsushi Takagi
- 16 October 2001
- journal article
- other
- Published by Wolters Kluwer Health in Circulation
- Vol. 104 (16) , 1917-1922
Abstract
Background Determination of fractional flow reserve (FFR) has been proposed as a means to assess stent deployment. In this prospective, multicenter trial, we evaluate the use of FFR to optimize stenting by comparing it with standard intravascular ultrasound (IVUS) criteria. Methods and Results Eighty-four stable patients with isolated coronary lesions underwent coronary stent deployment starting at 10 atm and increased serially by 2 atm until the FFR was ≥0.94 or 16 atm was achieved. IVUS was then performed. FFR was measured with a coronary pressure wire with intracoronary adenosine to induce hyperemia. The diagnostic characteristics of an FFR 30 μg) of intracoronary adenosine during pressure measurements, suggesting that FFR might be overestimated in the other group. Conclusions A fractional flow reserve <0.96, measured after stent deployment, predicts a suboptimal result based on validated intravascular ultrasound criteria; however, an FFR ≥0.96 does not reliably predict an optimal stent result. Higher doses of intracoronary adenosine than previously used to measure FFR improve these results.Keywords
This publication has 9 references indexed in Scilit:
- Use of fractional myocardial flow reserve to assess the functional significance of intermediate coronary stenosesThe American Journal of Cardiology, 2000
- Practice and potential pitfalls of coronary pressure measurementCatheterization and Cardiovascular Interventions, 2000
- Analysis of the relation between stent implantation pressure and expansionThe American Journal of Cardiology, 1999
- Impact of intravascular ultrasound guidance in stent deployment on 6-month restenosis rate: a multicenter, randomized study comparing two strategies—with and without intravascular ultrasound guidanceJACC, 1998
- Intravascular Ultrasound Predictors of Angiographic Restenosis in Lesions Treated With Palmaz-Schatz StentsJACC, 1998
- Practical Set-up of Coronary Pressure Measurement1997
- Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery StenosesThe New England journal of medicine, 1996
- Intracoronary Stenting Without Anticoagulation Accomplished With Intravascular Ultrasound GuidanceCirculation, 1995
- Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenosis severity before and after percutaneous transluminal coronary angioplasty.Circulation, 1993