Evaluation of optic nerve sheath diameter in patients undergoing robotic hysterectomy in steep Trendelenburg position compared to open abdominal hysterectomy in supine position: A randomized controlled trial
Authors:
Open Access
- 23 January 2025
- journal article
- Published by Wolters Kluwer Health in Journal of Anaesthesiology Clinical Pharmacology
- Vol. 41 (1) , 133-139
Abstract
Background and Aims: Raised intracranial pressure (ICP) is believed to be one of the side effects of prolonged Trendelenburg position in robotic gynecologic surgeries. Optic nerve sheath diameter (ONSD) corresponds to a rise in ICP. However, the data from robotic hysterectomy surgeries is limited. So, we had planned this study with an aim to detect and compare the change in ONSD during prolonged steep Trendelenburg position in robotic hysterectomy compared to open total abdominal hysterectomy in a supine position. Material and Methods: This was a prospective, observational, parallel-group, single-center study. Patients undergoing elective robotic hysterectomy and open total abdominal hysterectomy were included in this study. ONSD, end-tidal carbon dioxide (EtCO2), heart rate, and mean arterial pressure were assessed in both the groups after intubation (T0), after steep Trendelenburg position (T1), at 30 min (T2), 90 min (T3), and 180 min after docking (T4), and at the completion of surgery (de-docking) (T5). In patients undergoing open hysterectomy, the same parameters were recorded immediately after intubation (T0), at skin incision (T1), at 30 min (T2), 90 min (T3), and 180 min after skin incision (T4), and at the completion of surgery (T5). Results: Compared to the patients undergoing open hysterectomy, robotic hysterectomy patients had a significantly higher ONSD at time points T2, T3, and T4, with the maximum difference noted at the time point T4. EtCO2 was higher in patients undergoing robotic hysterectomy, though the difference was significant only at time point T2. No patient in our study had any symptom or sign of raised ICP in the postoperative period. Conclusion: The steep Trendelenburg position used in robotic hysterectomy causes a significant increase in ONSD intraoperatively, and that the changes are reversible after the procedure. Further, we did not observe any complication of raised ICP postoperatively.Keywords
This publication has 18 references indexed in Scilit:
- Noninvasive and quantitative intracranial pressure estimation using ultrasonographic measurement of optic nerve sheath diameterScientific Reports, 2017
- Detection of Elevated Intracranial Pressure in Robot-assisted Laparoscopic Radical Prostatectomy Using Ultrasonography of Optic Nerve Sheath DiameterJournal of Neurosurgical Anesthesiology, 2015
- Ultrasonographic Optic Nerve Sheath Diameter Is Correlated With Arterial Carbon Dioxide Concentration During Reperfusion in Liver Transplant RecipientsTransplantation Proceedings, 2013
- Optic Nerve Ultrasound for the Detection of Raised Intracranial PressureNeurocritical Care, 2011
- Ultrasonography of the optic nerve in neurocritically ill patientsActa Anaesthesiologica Scandinavica, 2011
- Reliability of Optic Nerve Ultrasound for the Evaluation of Patients with Spontaneous Intracranial HemorrhageNeurocritical Care, 2009
- Ultrasound of the eyeAustralasian Journal of Ultrasound in Medicine, 2009
- Correlation of Optic Nerve Sheath Diameter with Direct Measurement of Intracranial PressureAcademic Emergency Medicine, 2008
- Effects of Posture and Prolonged Pneumoperitoneum on Hemodynamic Parameters during LaparoscopyWorld Journal of Surgery, 2008
- Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injuryIntensive Care Medicine, 2007