Through-thickness creep damage in a service-exposed header of 2.25Cr1 Mo steel

Authors:
  • RWRui Wu
    Rui Wu
  • RSRolf Sandström
    Rolf Sandström
  • JSJan Storesund
    Jan Storesund

Abstract
A creep damage investigation was made on a service-exposed header of 2.25Cr 1Mo steel with a service time of 200 000 h. Weldments and the flanged parts at both outer and inner surfaces were studied as well as the damage in the through-thickness direction. Extensive cavitation was observed not only at the outer surface, but also well inside the component in the weldments. A model for the prediction of rupture position is introduced to explain the appearance of the observed creep damage.

This publication has 6 references indexed in Scilit: