Experimental and Mechanism Study on Axial Compressive Performance of Double Steel Tube Columns Filled with Recycled Concrete Containing Abandoned Brick Aggregate
Open Access
Abstract
Recycled concrete is widely recognized as favorable for environmental protection and sustainable development. However, recycled concrete, especially containing abandoned brick aggregate, is rarely used in main structural members due to its inherent defects. Concrete-filled double steel tube columns (CFDSTCs), consisting of an outer and an inner steel tube with concrete filling the entire section, are effective in load bearing and deformation resistance. The structural application of abandoned brick aggregate, resulting from urbanization renewal, might be widened through CFDSTCs. This paper presents an experimental and analytical study aiming to investigate the axial compressive behavior of recycled-brick-aggregate-concrete-filled double steel tube columns (RBCDSTs). A total of six specimens were tested under concentric compression, including five RBCDSTs and one concrete-filled single steel tube column. The varied parameters included the replacement ratios (0% and 25%) of brick aggregate and the thickness ratio of the inner and outer steel tubes (0.75, 1, and 1.25). Theoretical analysis was also carried out. A new constitutive model of RBCDST was proposed and used in finite element analysis. The investigation indicated that, under the current conditions, the presence of the inner steel tube only increased the strength by 0.14%. When the inner and outer diameter ratio is 0.73, using a 25% replacement rate of bricks in the entire cross-section or only in the ring area of the cross-section will result in 21.1% and 10.1% strength decreases, respectively. For every 0.6% increase in the diameter-to-thickness ratio of the outer tube, the strength of RBCDST increases 16.3% on average.Keywords
Funding Information
- Liaoning Province Natural Science Foundation Project of China (2024-MS-209)
This publication has 52 references indexed in Scilit:
- Prediction model on compressive strength of recycled aggregate concrete filled steel tube columnsComposites Part B: Engineering, 2019
- Strength and ductility improvement of recycled aggregate concrete by polyester FRP-PVC tube confinementComposites Part B: Engineering, 2019
- Experimental Study on the Behavior of Recycled Concrete-Filled Thin-Wall Steel Tube Columns Under Axial CompressionArabian Journal for Science and Engineering, 2018
- Behavior of glass and carbon FRP tube encased recycled aggregate concrete with recycled clay brick aggregateComposite Structures, 2016
- Effect of the quality of parent concrete on the properties of high performance recycled aggregate concreteConstruction and Building Materials, 2015
- Durability performance of concrete with recycled aggregates from construction and demolition waste plantsConstruction and Building Materials, 2015
- Stress–strain model for normal- and light-weight concretes under uniaxial and triaxial compressionConstruction and Building Materials, 2014
- Mechanical and durability properties of concretes containing recycled lime powder and recycled aggregatesConstruction and Building Materials, 2014
- Influence of the amount of recycled coarse aggregate in concrete design and durability propertiesConstruction and Building Materials, 2011
- Strain of concrete at peak compressive stress for a wide range of compressive strengthsMaterials and Structures, 1994