Quantitative Raman Reaction Monitoring Using the Solvent as Internal Standard
Authors:
- 29 January 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (5) , 1228-1236
Abstract
Despite its potential, the use of Raman spectroscopy for real-time quantitative reaction monitoring is still rather limited. The problems of fluorescence, laser instability, low intensities, and the inner filter effect often outscore the advantages as narrow bands, the use of glass fibers, and low scattering of water and glass. In this paper, we present real-time quantitative monitoring of the catalyzed Heck reaction by using the solvent as internal standard. In this way, all multiplicative distortions, e.g., laser intensity variations or absorbance of the laser light, can be corrected for. We also show that a limited amount of fluorescence does not hamper the analysis. Finally, we present a new method to correct for the inner filter effect, i.e., the absorbance of Raman scattered light by the reaction medium. Simultaneous absorption measurements of the reaction mixture enable accurate correction of Raman signals for the inner filter effect. Thus, for reaction monitoring applications, a Raman spectrometer should be equipped with an absorbance measurement device.Keywords
This publication has 12 references indexed in Scilit:
- Automated Fluorescence Rejection Using Shifted Excitation Raman Difference SpectroscopyApplied Spectroscopy, 2002
- Time‐resolved in situ Raman spectroscopy of working catalysts: sulfated and tungstated zirconiaJournal of Raman Spectroscopy, 2002
- Comparison of in-line NIR, Raman and UV-visible spectrometries, and at-line NMR spectrometry for the monitoring of an esterification reactionThe Analyst, 2002
- On-Line Analysis Using Raman Spectroscopy for Process Control during the Manufacture of Titanium DioxideApplied Spectroscopy, 2001
- Curve Fitting and Linearity: Data Processing in Raman SpectroscopyApplied Spectroscopy, 2001
- Raman spectroscopy: A technique for estimating extent of polymerization in PMMAMaterials Research Innovations, 2001
- Raman SpectroscopyAnalytical Chemistry, 2000
- FT-Raman spectroscopy — analytical tool for routine analysis of diazinon pesticide formulationsTalanta, 2000
- Identifications and Quantitative Measurements of Narcotics in Solid Mixtures Using Near-IR Raman Spectroscopy and Multivariate AnalysisJournal of Forensic Sciences, 1999
- Quantitative analysis using Raman spectroscopy without spectral standardizationJournal of Raman Spectroscopy, 1999